background image

FIREFRONT

This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow under
the firebed for the correct functioning of this appliance.

Compliance with safety standards cannot be guaranteed if another style of front is used.

CLEARANCES TO COMBUSTIBLES

A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given
below.

A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.

Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the
appliance, providing the forward projection does not exceed 100mm (4in).

Any combustible side walls must be at least 500mm to the side of the radiant heat source.

As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and
embossed paper) positioned too close to the appliance may discolour or scorch.

VENTILATION

No purpose provided ventilation is normally required for this appliance. The requirements of other appliances
operating in the same space or room, and the results of a spillage test must be taken into consideration when
assessing ventilation requirements, this will have been carried out by your CORGI registered installer.

For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.

OPERATING INSTRUCTIONS

The pilot is visible through the underside of the left hand front coal strip. Push
in and turn the control knob to the SPARK position, and hold there for a few
seconds.

Continue turning anti-clockwise through the spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat.

When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot should stay
alight. If not, repeat ignition. If the pilot is extinguished during use, wait three
minutes before repeating the ignition procedure.

To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to the high
position. The main burner should light after a few seconds.

To decrease the setting to LOW, turn the control knob clockwise to the low setting.

To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot
position and release.

To turn the fire OFF, keep the knob pressed in, return to
the off position and release.

2

Maximum depth of shelf                    Minimum distance from inside edge of

fire frame to underside of shelf

100mm (4in)

203mm (8in)

150mm (6in)

305mm (12in)

203mm (8in)

356mm (14in)

2.0

3.0

4.0

5.0

Содержание SUPA 400

Страница 1: ......

Страница 2: ......

Страница 3: ...a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions...

Страница 4: ...se regulations could lead to prosecution and deem the warranty invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult a...

Страница 5: ...ing a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only o...

Страница 6: ...ught device must be sealed off The opening wall must be non combustible and have adequate flat surface for appliance sealing The appliance requires a hearth with non combustible surface of at least 12...

Страница 7: ...ID FUEL OR OIL BURNING APPLIANCES X Dimension 60mm VENTILATION No purpose provided ventilation is normally required for this appliance The requirements of other appliances operating in the same room o...

Страница 8: ...hearth may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any b...

Страница 9: ...g the two screws through the tray legs Remove the transit screw securing the rear ledge of the firetray to the firebox This will no longer be required The tray is now free and may be lifted away Knock...

Страница 10: ...ion SCREW FIXING For fixing by screw mark and drill the fireframe or base and the relevant points in the opening or on the wall Rawlplugs will again be required Pre punched holes are not provided for...

Страница 11: ...e loose tensioning cables through the holes into the firebox You may need to temporarily adjust the outlet deflector at this point as described in the Fitting the firebox section Thread the tensioner...

Страница 12: ...ng the coal shapes are facing forwards The legs on the coals have a serrated front face which is intended to give a tight interference fit in to the tray and at the same time remove a small portion of...

Страница 13: ...ifferent type Never throw rubbish or other matter onto the coal bed FITTING THE DECORATIVE FRAME AND FRONT The appliance is supplied with a decorative frame in a variety of finishes The frame is held...

Страница 14: ...taper FLAME CONTROL LEVER On Natural Gas appliances there is a flame control lever behind the ashpan door that varies the flame colour from blue to a decorative yellow The customer should be instructe...

Страница 15: ...ce manufacturer If the fire is not spilling then further guidance should be sought using the Troubleshooting section as a guide TESTING FOR SPILLAGE Close all doors and windows to the room containing...

Страница 16: ...trol plate 5 Disconnect the gas supply and remove the two securing screws in the tray legs 6 Remove the burner tray 7 Remove the firebox as detailed in the relevant section 8 Check the area behind the...

Страница 17: ...remove the largest of the three screws on the face of the valve Slide the filter out and clean away any debris that may have accumulated The filter element should also be blown clean This component sh...

Страница 18: ...lderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant...

Страница 19: ...is will have been carried out by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS The pilo...

Страница 20: ...the firebed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This should be repaired by a competent person and the fire serviced before furt...