FUEL BED LAYOUT (continued)
Place the second row of six coals on the placement pads
behind the first row of coals as shown. These coals MUST
NOT impede the flames passing through the rear flame
holes of the matrix. Ensure that no corners of coals or
rough edges project back into the slots. Move the coals
forward away from the slots if at all unsure.
Place the final row of five coals across the matrix on the
remaining placement pads. These coals MUST NOT be
allowed to fall into the flame slots in the matrix, and MUST
have gaps between them to let the flames through.
Note: The coals must not be crammed together, or inserted
into the holes in the matrix. A well laid out, generously
spaced coal layout will give the best results.
Coals may be rotated slightly within their positions to give a good visual effect.
The fire is designed to operate correctly with the coals supplied when assembled according to the instructions.
Never add to the twenty-two coals, or change them for a different type. Never throw rubbish or other matter onto
the coal bed.
FITTING THE DECORATIVE FRAME AND FRONT
The appliance is supplied with a decorative frame in a variety of
finishes. The frame is held onto the firebox by one of two methods;
either by magnetic pieces fitted to the steel backing plates, or as a
three piece clip-on assembly.
If not pre-fitted, the clip-on frame pieces should be hooked over the
outer edges of the fireframe, and pushed firmly home. The sides
should be fixed first, followed by the top bar, which overlaps the sides.
Push firmly home.
A plastic protective film may be applied to the outside of the frame
and should be removed at this stage.
Place the decorative firefront in front of the fire and slide the ashpan
door into place. The firefront shown in these instructions may be
different to the one supplied with the appliance.
TESTING AND COMMISSIONING
Turn on and test the gas supply up to the fire for any leaks, in accordance with current Approved Codes Of
Practice (ACOPs).
When the appliance is first used, protective oils coating the firebox may burn off. It is advisable to ventilate the
room during this period, at least one hour.