USER INSTRUCTIONS

IMPORTANT NOTES

The installation of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter)
in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes
of Practice, the Building Regulations and the manufacturers’ instructions.

Failure to comply with the above recommendations could lead to prosecution and invalidate the appliance
warranty.

Please ensure you are handed all of the manufacturers documents on completion of the installation. This will
include these instructions.

Always keep a note of the installer’s name and address, the original purchase receipt and the date of installation
for future reference.

The fire and flue should be serviced regularly to ensure continued safe operation. See the servicing section for
further details. Frequency of service will depend on use, but MUST be carried out at least once annually.

Parts of this appliance become naturally hot during use. It is recommended that a suitable fire guard conforming
to BS 6778 or 6539 is used, especially where young children, the elderly, or infirm are concerned.

Combustible items, such as flooring and furniture, and soft wall coverings (such as blown vinyl or embossed
paper) may discolour if fitted too close to the fire. See relevant section for further details on clearances to
combustibles. No combustible material or flooring should protrude onto the hearth.

DO NOT burn any foreign material on this fire, the coals must be of the correct type and laid out in accordance
with the relevant section of these instructions. Failure to do so could create a hazard or lead to sooting.

Before the appliance is installed, the chimney should be swept. All flues should be checked by the installer to
ensure there are no defects or obstructions that may prevent the flow of combustion products.

This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions
occur. It is NOT a substitute for an independently mounted Carbon Monoxide detector.

The fire is only suitable for use with the gas type for which it is supplied.

1

Section

1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0

10.0

Contents

Important Notes
Firefront
Clearances to Combustibles
Ventilation
Operating Instructions
Flame Control Lever
Flue Spillage Monitoring System
Cleaning
Coals and Ceramics
List of Spares

Page No.

1
2
2
2
2
3
3
3
3
3

1.0

Содержание SUPA 400

Страница 1: ......

Страница 2: ......

Страница 3: ...a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions...

Страница 4: ...se regulations could lead to prosecution and deem the warranty invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult a...

Страница 5: ...ing a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only o...

Страница 6: ...ught device must be sealed off The opening wall must be non combustible and have adequate flat surface for appliance sealing The appliance requires a hearth with non combustible surface of at least 12...

Страница 7: ...ID FUEL OR OIL BURNING APPLIANCES X Dimension 60mm VENTILATION No purpose provided ventilation is normally required for this appliance The requirements of other appliances operating in the same room o...

Страница 8: ...hearth may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any b...

Страница 9: ...g the two screws through the tray legs Remove the transit screw securing the rear ledge of the firetray to the firebox This will no longer be required The tray is now free and may be lifted away Knock...

Страница 10: ...ion SCREW FIXING For fixing by screw mark and drill the fireframe or base and the relevant points in the opening or on the wall Rawlplugs will again be required Pre punched holes are not provided for...

Страница 11: ...e loose tensioning cables through the holes into the firebox You may need to temporarily adjust the outlet deflector at this point as described in the Fitting the firebox section Thread the tensioner...

Страница 12: ...ng the coal shapes are facing forwards The legs on the coals have a serrated front face which is intended to give a tight interference fit in to the tray and at the same time remove a small portion of...

Страница 13: ...ifferent type Never throw rubbish or other matter onto the coal bed FITTING THE DECORATIVE FRAME AND FRONT The appliance is supplied with a decorative frame in a variety of finishes The frame is held...

Страница 14: ...taper FLAME CONTROL LEVER On Natural Gas appliances there is a flame control lever behind the ashpan door that varies the flame colour from blue to a decorative yellow The customer should be instructe...

Страница 15: ...ce manufacturer If the fire is not spilling then further guidance should be sought using the Troubleshooting section as a guide TESTING FOR SPILLAGE Close all doors and windows to the room containing...

Страница 16: ...trol plate 5 Disconnect the gas supply and remove the two securing screws in the tray legs 6 Remove the burner tray 7 Remove the firebox as detailed in the relevant section 8 Check the area behind the...

Страница 17: ...remove the largest of the three screws on the face of the valve Slide the filter out and clean away any debris that may have accumulated The filter element should also be blown clean This component sh...

Страница 18: ...lderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant...

Страница 19: ...is will have been carried out by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS The pilo...

Страница 20: ...the firebed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This should be repaired by a competent person and the fire serviced before furt...

Отзывы: