background image

FLAME CONTROL LEVER

On Natural Gas appliances there is a flame control lever behind the ashpan door that varies the flame colour from
blue to a decorative yellow. This lever can be used to vary the flame picture as required. To minimise any carbon
deposition that may occur, it is recommended that the fire is used on the COKE setting for the first and last
periods (approximately 20 mins.) of each use.

FLUE SPILLAGE MONITORING SYSTEM

This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason
then several reasons may be suspected. If a door or window has been opened creating a draught, then pilot
disturbance could be the problem, and removal of the draught should resolve this. The fire can then be re-lit in
accordance with the previous section. A sealing grommet may have been ommited when the fire was installed,
and the original installer should be called to check this, the gas pressure and pipework.

If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF,
call in your installer to check the flue and ventilation and carry out any remedial work required. DO NOT allow
the appliance to be used until the flue system is passed as safe.

CLEANING

Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.

Debris that may form on the firebed should be periodically removed by a competent person. Large deposits
could indicate deterioration of the flue. This should be repaired by a competent person, and the fire serviced
before  further use.

FIREFRAME - This is retained by one of two methods, either by magnetic backing pieces, or a three piece clip-on
assembly. The magnetic frame may be removed for cleaning if required, however the clip-on style must not be
removed. A wipe with a dry cloth is normally sufficient, but on stains it is permissible to use a damp cloth with a
mild household cleaner, followed by a wipe with a dry cloth. DO NOT use abrasive cleaners as these may
damage the finish. To re-assemble ensure the magnets are place on the steel backing pieces, and re-fit to the
firebox.

FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or dry cloth. Heavy
stains may be removed by using a damp cloth and mild household detergent. Brass parts of the firefront may be
cleaned using a suitable brass cleaner. Replace the front centrally against the fire after cleaning.

PAINTED AREAS - These can be cleaned using a dry cloth.

COALS AND CERAMICS

See the relevant section in the Installation Guide of these instructions. Do not create dust from the coals. Clean
gently in the open air. Replace components with original spares only as necessary.

LIST OF SPARES

PART NO.

ITEM

FT003035/0

Pack of 22 coals

FT003040/0

Pair of front coal strips

FT003010/0

Ceramic combustion matrix

IN004540/0

Burner Pad

Enquire

Decorative Frame

Enquire

Decorative Front

3

6.0

7.0

8.0

10.0

9.0

Part No : FF440

Содержание SUPA 400

Страница 1: ......

Страница 2: ......

Страница 3: ...a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions...

Страница 4: ...se regulations could lead to prosecution and deem the warranty invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult a...

Страница 5: ...ing a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only o...

Страница 6: ...ught device must be sealed off The opening wall must be non combustible and have adequate flat surface for appliance sealing The appliance requires a hearth with non combustible surface of at least 12...

Страница 7: ...ID FUEL OR OIL BURNING APPLIANCES X Dimension 60mm VENTILATION No purpose provided ventilation is normally required for this appliance The requirements of other appliances operating in the same room o...

Страница 8: ...hearth may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any b...

Страница 9: ...g the two screws through the tray legs Remove the transit screw securing the rear ledge of the firetray to the firebox This will no longer be required The tray is now free and may be lifted away Knock...

Страница 10: ...ion SCREW FIXING For fixing by screw mark and drill the fireframe or base and the relevant points in the opening or on the wall Rawlplugs will again be required Pre punched holes are not provided for...

Страница 11: ...e loose tensioning cables through the holes into the firebox You may need to temporarily adjust the outlet deflector at this point as described in the Fitting the firebox section Thread the tensioner...

Страница 12: ...ng the coal shapes are facing forwards The legs on the coals have a serrated front face which is intended to give a tight interference fit in to the tray and at the same time remove a small portion of...

Страница 13: ...ifferent type Never throw rubbish or other matter onto the coal bed FITTING THE DECORATIVE FRAME AND FRONT The appliance is supplied with a decorative frame in a variety of finishes The frame is held...

Страница 14: ...taper FLAME CONTROL LEVER On Natural Gas appliances there is a flame control lever behind the ashpan door that varies the flame colour from blue to a decorative yellow The customer should be instructe...

Страница 15: ...ce manufacturer If the fire is not spilling then further guidance should be sought using the Troubleshooting section as a guide TESTING FOR SPILLAGE Close all doors and windows to the room containing...

Страница 16: ...trol plate 5 Disconnect the gas supply and remove the two securing screws in the tray legs 6 Remove the burner tray 7 Remove the firebox as detailed in the relevant section 8 Check the area behind the...

Страница 17: ...remove the largest of the three screws on the face of the valve Slide the filter out and clean away any debris that may have accumulated The filter element should also be blown clean This component sh...

Страница 18: ...lderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant...

Страница 19: ...is will have been carried out by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS The pilo...

Страница 20: ...the firebed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This should be repaired by a competent person and the fire serviced before furt...

Отзывы: