If running a concealed gas supply, ensure grommets are secure around incoming pipes.
Important Note: Check the thermocouple nut connection into the rear of the valve is secure.
Please refer to section 7.0 of the user instructions.
All models : Remove all protective film and packaging material before fitting.
One-piece frame models : The appliance is supplied with a one piece decorative frame that
is attached to the front of the firebox with the magnets provided. Position the firefront in front
of the burner.
Three-piece frame models :The clip-on frame pieces should be hooked over the outer edges
of the fireframe, (figure 12), and pushed firmly home. The sides should be fixed first, followed by
the top bar, which overlaps the sides. Push firmly home.
IMPORTANT : Due to the possibility of sharp edges, care should be taken when han-
dling the three-piece frame components. The use of protective gloves is strongly rec-
ommended.
Cast frame models : Remove the decorative frame from it’s protective packaging. The frame is retained onto the firebox with a mount-
ing bracket at the top of the frame and three magnets on each leg of the frame.
Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS6891. When the appliance is first
used, protective oils coating the firebox may burn off. It is advisable to ventilate the room during this period for at least one hour.
The pilot is visible through the left hand side of ceramic fuel matrix. When cold, the coals or pebbles may be rotated for good viewing.
The fire features a ‘twin spark’ ignition system to aid lighting,
Push the control knob in fully and turn anti-clockwise through both of the SPARK positions, keep-
ing fully depressed, hold there for a few seconds. If the fire has not been used for some time, hold
the knob in this position for longer, to allow any air in the pipes to be purged.
Continue turning anti-clockwise through the spark clicks to the nine o’clock position, ensuring
the pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after one of the two sparks, keep the knob depressed in the nine o’clock
position for approximately ten seconds. Now release the knob and the pilot should stay alight. If
the pilot is extinguished during use, wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clock-
wise to the high position. The main burner should light after a few seconds. To decrease the set-
ting to LOW, push the knob in slightly and turn the control knob clockwise to the low setting.
To turn to the pilot only position from the HIGH or LOW positions, press the control knob in, and return to the nine o’clock position
and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.
The pilot is visible through the left hand side of the matrix. When cold, the coals or pebbles may be rotated for good viewing.
Turn the main burner control (shown on left hand side of control valve) knob fully
anti-clockwise.
Turn ignition knob (shown on right hand side of control valve) slightly left towards
the ignition position until reaching the stop, press down and hold for 5 seconds
(only pilot gas is flowing)
Continue pressing down the knob while turning further to the left to activate the
piezo spark, continue to hold the knob down for a further 10 seconds after the
pilot has been lit. If the pilot does not light repeat the previous steps.
8
© 2016 Focal Point Fires plc.
13.0 GAS CONNECTION
14.0 FUEL BED LAYOUT
16.0 TESTING AND COMMISSIONING
15.0 FITTING THE FIREFRONT/FRAME
Figure 12
GB IE
16.1 OPERATING THE FIRE - MANUAL CONTROL MODELS
16.2 OPERATING THE FIRE - REMOTE CONTROL MODELS
Figure 13
Figure 14