11
Remove the firefront and place to one side. Remove the ceramic components. Gently clean in the open air. Be careful not to create dust
from the coals. Where necessary replace damaged components with genuine spares. Seal scrap ceramic components in plastic bags and
dispose at proper refuse sites as directed.
Re-fit the ceramic fuel bed by referring to the relevant section of these instructions.
Remove the firefront. Remove the ceramics and place safely aside.
Manual control models : Remove the two screws securing the tray legs to the firebox. Pull tray forward slightly and lift away.
Slide control models : Remove the four screws securing the tray to the firebox (two in the tray legs and two in the rear of the tray
- see figure 10). Remove the M4 nut from the slide control linkage. Pull tray forward slightly and lift away. When re-fitting replace the
rear retaining screws first, followed by the front (leg) retaining screws.
All models : Be sure to engage the tray location lugs on the shelf at the rear of the firebox.
Remove the tray as previously described. The pilot unit can be removed by withdrawing the tubing nut, the thermocouple nut on the
valve, and the two securing screws, and lifting away. Remove the tubing nut from the valve end of the pilot pipe, and blow through to dis-
lodge any debris. Remove the two tubing nuts on the ends of the gas pipe to the injector elbow and blow clear. Remove the two tub-
ing nuts on the ends of the inlet pipe and blow clear.
Manual control models : The valve is not field serviceable.
Slide control models : The valve contains a gauze filter on the inlet manifold. Check that this is free from debris/obstruction.
Remove the burner unit as previously described. The pilot unit can be removed by withdrawing the tubing nut, the thermocouple nut on
the rear of the valve, and the two securing screws, and lifting away. Remove the tubing nut from the valve end of the pilot pipe, and blow
through to dislodge any debris.
Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly
internally, the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier. Do not damage
or try to remove the pilot injector. The unit is factory set and the only check necessary is to ensure the spark gap is correct. See spec-
ifications for gap setting.
Remove the burner unit. Protect the hearth from potential damage. Unroll the coiled tensioner cables from the rear of the firebox.
Remove the securing nipples and tensioner adjusters. The firebox is now released from the opening and can be slid outward onto the
hearth. Inspect the fireplace opening for debris and if excessive rectify the flue before proceeding further. Check the seal around the fire-
frame and if necessary replace. Refitting of the firebox is as described in the fitting section of these instructions.
Handset - Remove cover from rear of handset and insert 1 x ‘PP3’ (9 volt) battery - Replace
cover
Appliance - Ensure appliance is off and cool. Remove cover from top of receiver box. The
cover is protected by reflective foil, and located towards the right hand side, underneath the
burner unit. Insert 4 x ‘AA’ (1.5 volt) batteries - Replace cover.
Slide control models
Ensure appliance is off and cool. The battery is located in the front of the ignition unit, on
the right hand side of the burner (shown in figure 21). Unscrew the battery holder cap. Insert 1
x ‘AA’ (1.5 volt) battery. Replace cap.
© 2016 Focal Point Fires plc.
17.1 CLEANING THE CERAMICS
17.2 REMOVING THE BURNER
17.4 PILOT ASSEMBLY
17.5 REMOVING THE FIREBOX
GB IE
17.6 REPLACING THE BATTERIES
(REMOTE CONTROL VERSIONS)
17.3 DISMANTLING THE BURNER
Figure 20
17.7 REPLACING THE BATTERIES
(SLIDE CONTROL VERSIONS)
Figure 21