The pilot is visible through the left hand side of
the matrix. When cold, the coals or pebbles may
be rotated for good viewing.
Turn the main burner control (shown on left hand
side of control valve) knob fully anti-clockwise.
Turn ignition knob (shown on right hand side of
control valve) slightly left towards the ignition
position until reaching the stop, press down and
hold for 5 seconds (only pilot gas is flowing)
Continue pressing down the knob while turning further to the left to activate the piezo spark, contin-
ue to hold the knob down for a further 10 seconds after the pilot has been lit. If the pilot does not light
repeat the previous steps.
Upon lighting and after the further 10 seconds, release the knob and turn further to the left to the ON
position. The main burner will light and be controlled in accordance with the main burner control knob
setting. Adjust the main burner control knob to the desired setting. If the pilot is extinguished during
use of the fire, you MUST wait ten minutes before repeating the ignition procedure.
To turn the main burner OFF whilst keeping the pilot flame lit, turn the ignition control knob to the
pilot position then only the pilot will remain lit.
To shut the fire off completely, press the ignition control knob down and continue turning to the right
from the pilot position to the OFF position.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled sufficiently to allow the magnetic valve unit to
reset itself. The remote control unit allows operation of the main burner setting between maximum and pilot only setting. It does not per-
manently turn the pilot on or off.
The remote control handset incorporates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally. It is
necessary to press button 1 and 2 (see figure 5) simultaneously to turn the fire up. To turn the fire down press button 3 only.
The pilot is visible through the left hand side of the matrix. When cold, the coals or pebbles may be
rotated for good viewing.
Push the slide control knob fully downwards to the SPARK position, and hold there for approximately
ten seconds. Now release the knob and the pilot should stay alight. When the pilot light has established,
move the slide control knob upwards to the LOW flame setting. If the pilot is extinguished during use,
wait three minutes before repeating the ignition procedure.To achieve the HIGH setting, move the slide
control knob upwards to the HIGH flame setting. The fire can also be set to operate anywhere between
HIGH and LOW by moving the control knob to an intermediate position.
To turn the fire OFF, move the slide control knob upwards fully to the position marked ‘O’.
This fire is fitted with a flue spillage safety device (ODS).
If the fire shuts down during use for no apparent reason then several reasons may be suspected. If a door or window has been opened cre-
ating a draught, then pilot disturbance could be the problem, and removal of the draught should resolve this.
The fire can then be re-lit in accordance with the previous section. If pilot disturbance is not the cause, then the ODS safety system may be
in operation. Switch the appliance OFF, call in your installer to check any ventilation and carry out any remedial work required. DO NOT
allow the appliance to be used until the installation is passed as safe.
3