No purpose provided ventilation is normally required for this appliance. The requirements of other appliances operating in the

same room or space must be taken into consideration when assessing ventilation. If spillage is detected when commissioning the appli-

ance, then amongst other problems there may be insufficient natural ventilation for correct operation of the flue. If the appliance does

not spill with the windows open, but spillage is detected with the windows closed, this demonstrates a lack of natural ventilation. If

spillage is still detected with the windows open, the flue is at fault. Installation of an air brick is the best solution to lack of ventilation.

Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Vents fitted under or within the immediate vicinity of the

appliance must not be used as adverse effects to the operation of the ODS may occur. Spillage detected during commissioning is almost

always a result of poor flue performance that cannot be corrected by any amount of ventilation. For Republic of Ireland ventilation may

be required, see IS 813, ICP3, IS 327, and any other rules in force.

This  appliance  can  be  fitted  into  a  number  of  proprietary  flue

boxes provided that the minimum dimensions shown in figure 2

are complied with.

Constructional Note: The frame of the fire, any back panel or

other infill panels, and the flue box must be sealed together so that

there is no possibility of leakage between them. Adequate clear-

ances  to  combustible  materials  (e.g.  false  chimney  breast  con-

struction) must be maintained.

The  manufacturers’  instructions  for  fitting  the  prefabri-

cated box shall be complied with at all times. To fit the fire

using the cable fixing kit, some minor adaption may be necessary

for certain flue boxes. A check should be made to ensure the fire-

box does not obscure the flue box outlet. The firebox, base of the

flue  box,  and  hearth  below  may  be  drilled  to  allow  plugs  and

screws  to  secure  installation.  It  is  important  that  the  sealing

requirements of the appliance are met at all times and that the flue

box is well sealed to any back or infill panel. Note: The DEPTH

dimension is inclusive of any back or infill panel.

Stand the carton the right way up, cut the strapping bands and remove the top endcap. Read all the instructions before continuing to

unpack or install this appliance. Remove the box containing the firefront, and the bags containing the ceramic components. Remove the

cardboard packing pieces, and any other bags or boxes containing fittings or other parts. When all loose parts have been removed, the

outer sleeve may be lifted off to reveal the appliance. Check that the components supplied correlate with the component checklist given

in section 7.1. Please dispose of all the packaging materials at your local recycling centre.

5.0 VENTILATION

GB IE

6.0 PREFABRICATED FLUE BOXES

125mm min internal dia. twin wall flue

Radiant models:

128mm min

depth

Convector

models:

140mm min

depth

Radiant models: 350mm min opening width

Convector models: 380mm min opening width

540mm

min height

Figure 2

7.0 UNPACKING THE APPLIANCE

7.1 COMPONENT CHECKLIST

QUANTITY

DESCRIPTION

1

Firebox and burner tray assembly

1

Decorative frame

1

Firefront

1

Black Moulded ceramic fibre combustion matrix (coal effect versions only)

1

Beige Moulded ceramic fibre combustion matrix (Pebble effect version only)

11

Individual ceramic coals (rounded coal effect version only)

15

Individual ceramic coals (ripped coal effect version only)

15

Individual ceramic pebbles (pebble effect  version only)

2

Ceramic fibre side cheeks (pebble effect & ripped coal effect)

1

Ceramic rear panel

1

Ceramic taper pad (radiant models only)

1

Remote control handset (remote control models only)

1

Cable fixing kit; 2 cables, 2 tensioners, 2 cable clamps, 4 fixing eyes, 4 wall plugs

1

Sealing grommet

3

Lengths of adhesive sealing strip

1

Self tapping screw pack; 4 No.8 x 5/16

1

Spigot restrictor

1

Deflector baffle

1

Set of manufacturers instructions

1

Slide control position marking sticker (slide control models only)

1

Slide control knob and M4 Nyloc nut (slide control models only)

5

© 2016 Focal Point Fires plc.

Содержание GRANGE MULTIFLUE

Страница 1: ...t the prior written permission of Focal Point Fires plc 1 Revision A 08 16 2016 Focal Point Fires plc GB IE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www foc...

Страница 2: ...ion and use of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery o...

Страница 3: ...proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent...

Страница 4: ...ard projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall...

Страница 5: ...ation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any...

Страница 6: ...ontrol position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of the smoke should travel up the flue and...

Страница 7: ...the tensioner nuts to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it wi...

Страница 8: ...d for some time hold the knob in this position for longer to allow any air in the pipes to be purged Continue turning anti clockwise through the spark clicks to the nine o clock position ensuring the...

Страница 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Страница 10: ...g this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the inst...

Страница 11: ...on the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot assembly with a...

Страница 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will no...

Страница 13: ...installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if...

Страница 14: ...ing Push the control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the...

Страница 15: ...dset incorporates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally It is necessary to press button 1 and 2 see figure 5 simultaneously to turn the fire up...

Страница 16: ...be crammed together or inserted into the holes in the matrix A well laid out generously spaced coal layout will give the best results When lit the flames should not be hitting the sides of the firebo...

Страница 17: ...travel through the pebbles and are not obstructed by them No flames should hit the sides of the firebox IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled ac...

Страница 18: ...e fronts to rust Any dust accu mulating in the firefront may be removed using a vacuum cleaner or dry cloth OTHER FIREFRONTS Any dust accumulating in the fire front may be removed using a vacuum clean...

Страница 19: ...21100 Manual remote control slide control models F730108 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730067 Injector Stereo 78 Manua...

Страница 20: ...ance must have been serviced annually by Gas Safe registered installer evidence of which must be provided such as the receipt 4 Purchase s must be made through an authorised stockist retailer Please n...

Отзывы: