Lay out the pebbles and put the 4

largest to one side. Place any six

of  the  smaller  pebbles  on  the

front  row  of  the  matrix.  Ensure

the pebbles are firmly against the

side cheeks as shown in the pho-

tograph. If necessary, pull the peb-

bles  forward  slightly  to  ensure

their rear edges do not overhang

the flame ports. The edges of the

pebbles  MUST NOT be  allowed

to enter the flame ports.

Place the middle row of four larger pebbles onto the supports in the matrix, over

the top of the holes and partially on top of the front pebbles. Ensure the pebbles

are not turned sideways, such that they actually enter the holes.

Place the rear row of five pebbles on the flat posts of the matrix and up against the

middle row making sure there is a gap between them. It may be necessary to change

the orientation of these by 90 degrees. Note: The pebbles must not be crammed

together, or inserted into the holes in the matrix. A well laid out,  generously spaced

pebble layout will give the best results.

Make sure the flames travel through the pebbles and are not obstructed by them. No flames should hit the sides of the firebox

IMPORTANT :  

The fire is designed to operate correctly with the pebbles supplied when assembled according to the

instructions. Never add to the fifteen pebbles, or change them for a different type. Never throw rubbish or other

matter onto the fuel bed. Due to the light colour of the pebbles, some discolouration/sooting is to be expected dur-

ing normal use. 

This fire is supplied with 11 ceramic moulded coals. 

Fit the tapered brick pad into the securing brackets in the upper area of the fire-

box. Place the large brick panel against the rear of the firebox.

Place the ceramic combustion matrix onto the burner.

Lay out the coals and put the 4

largest to one side.

Place the front row of five small-

er coals on to the matrix. Ensure

that  the  coals  are  lined  up  with

the  port  walls.  The  rear  two

smaller coals are to be position in

the centre and pushed back. The

edges of the coals MUST NOT be

allowed to enter the flame ports.

5

© 2016 Focal Point Fires plc.

7.1 FUEL BED LAYOUT - PEBBLE EFFECT - CONTINUED

GB IE

Figure 14

Figure 16

Figure 15

7.2 FUEL BED LAYOUT - ROUNDED COAL EFFECT

Figure 17

Figure 19

Figure 18

Содержание GRANGE MULTIFLUE

Страница 1: ...t the prior written permission of Focal Point Fires plc 1 Revision A 08 16 2016 Focal Point Fires plc GB IE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www foc...

Страница 2: ...ion and use of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery o...

Страница 3: ...proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent...

Страница 4: ...ard projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall...

Страница 5: ...ation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any...

Страница 6: ...ontrol position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of the smoke should travel up the flue and...

Страница 7: ...the tensioner nuts to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it wi...

Страница 8: ...d for some time hold the knob in this position for longer to allow any air in the pipes to be purged Continue turning anti clockwise through the spark clicks to the nine o clock position ensuring the...

Страница 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Страница 10: ...g this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the inst...

Страница 11: ...on the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot assembly with a...

Страница 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will no...

Страница 13: ...installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if...

Страница 14: ...ing Push the control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the...

Страница 15: ...dset incorporates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally It is necessary to press button 1 and 2 see figure 5 simultaneously to turn the fire up...

Страница 16: ...be crammed together or inserted into the holes in the matrix A well laid out generously spaced coal layout will give the best results When lit the flames should not be hitting the sides of the firebo...

Страница 17: ...travel through the pebbles and are not obstructed by them No flames should hit the sides of the firebox IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled ac...

Страница 18: ...e fronts to rust Any dust accu mulating in the firefront may be removed using a vacuum cleaner or dry cloth OTHER FIREFRONTS Any dust accumulating in the fire front may be removed using a vacuum clean...

Страница 19: ...21100 Manual remote control slide control models F730108 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730067 Injector Stereo 78 Manua...

Страница 20: ...ance must have been serviced annually by Gas Safe registered installer evidence of which must be provided such as the receipt 4 Purchase s must be made through an authorised stockist retailer Please n...