All  models:  Drill  four  holes  using  a  8mm

masonry bit to a depth of 42mm in the posi-

tions   shown in figure 10. If the fireplace con-

figuration  does  not  allow  the  exact  layout

given,  the  eyebolts  should  be  positioned  as

close to the correct layout as possible. 

Before  finally  fitting  cables,  ensure  the  self

adhesive sealing strips are in position on the

back  of  the  appliance  frame.  The  fireframe

must be sealed evenly to the fireplace opening

all around the periphery. 

Thread  the  tensioning  cables  through  the

holes in the top of the firebox, then the eye-

lets, and finally through the lower holes in the

back of the firebox, as shown in figure 12. 

Note :  The burner must be removed as per relevant section to gain access to the cable adjusters.

Push the appliance back into the fireplace, centralise, and pull the loose tensioning cables through the

holes  into  the  firebox. You  may  need  to  temporarily  adjust  the  outlet  deflector  at  this  point  as

described in section 8.0 of these instructions. Thread the tensioner bolts onto the cables, with the

nuts screwed down close to the tensioner head. Slide the screwed nipple onto the cable, pull cable

tight, and tighten nipple.

The tension of the cable may now be adjusted by using a suitable spanner on the tensioner nuts to

pull the appliance tightly against the fireplace opening. Visually inspect the seal and reseat if necessary. 

Do not cut off excess cable. Surplus cable must not be cut off, as it will be impossible to refit the fire after servicing. Coil up the surplus

cable, and locate at rear of firebox as shown in figure 13. If running a concealed gas supply, ensure grommets are secure around incom-

ing pipes.

Important  Note: Check the thermocouple nut connection into the rear of the valve is secure.

Temporarily fit the burner unit and ensure a suitable gas route can be achieved. Purge the gas supply thoroughly to remove air and

dirt/debris before connection. Disconnect the inlet restrictor elbow from the inlet pipe. 

Connect the previously installed gas supply to inlet restrictor elbow. Place the burner unit into the firebox making sure that the rear

lugs locate properly on to the ledge in the firebox. Fit the two securing screws through the burner legs to secure the assembly. Re-fit

the restrictor elbow to the inlet pipe of the appliance.

Please see the relevant section of the user instructions.

All models : Remove all protective film and packaging material before fitting.
One-piece frame models : The appliance is supplied with a one piece decorative frame that
is attached to the front of the firebox with the magnets provided. Position the firefront in front
of the burner.
Three-piece frame models : The clip-on frame pieces should be hooked over the outer
edges of the fireframe, (figure 14), and pushed firmly home. The sides should be fixed first,  fol-
lowed by the top bar, which overlaps the sides. Push firmly home.  
IMPORTANT : Due to the possibility of sharp edges, care should be taken when
handling the three-piece frame components. The use of protective gloves is strong-
ly recommended.
Cast frame models : 
Remove the decorative frame from it’s protective packaging. The frame is retained onto the firebox with a mount-
ing bracket at the top of the frame and three magnets on each leg of the frame.

Turn on and test the gas supply up to the fire for any leaks, in accordance with current edition of BS6891.

When the appliance is first used, protective oils coating the firebox may burn off. It is advisable to ventilate the room during this period

for at least one hour.

11.1 INSTALLATION BY CABLE  FIXING KIT

GB IE

8

© 2013 Focal Point Fires plc.

‘A’

‘B’

‘C’

‘A’. 250 mm

‘B’. 350 mm

‘C’. 60 mm

All dims ±10mm

Figure 11

Figure 12

Figure 13

11.2 GAS CONNECTION

11.3 FUEL BED LAYOUT

12.0 TESTING AND COMMISSIONING

11.4 FITTING THE FIREFRONT/FRAME

Figure 14

Содержание ALVOR FULL DEPTH RADIANT

Страница 1: ...ekeeping Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt...

Страница 2: ...and under normal usage will need a new battery approximately every twelve months Burner spark generator requirements 1 x AA 1 5 volt Refer to the appropriate section of these instructions for details...

Страница 3: ...rom dam aging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and ter minals These appliances have been tested for use with...

Страница 4: ...may be fixed to the wall above the fire providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible ma...

Страница 5: ...ox does not obscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements...

Страница 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use...

Страница 7: ...siliconed When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet...

Страница 8: ...suitable gas route can be achieved Purge the gas supply thoroughly to remove air and dirt debris before connection Disconnect the inlet restrictor elbow from the inlet pipe Connect the previously inst...

Страница 9: ...mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the ceramic fuel bed When cold the coals or...

Страница 10: ...the HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in section 2 0 of these instructions The fire is factory set to achieve these pressures a...

Страница 11: ...ded during this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in...

Страница 12: ...t must be used If a large amount of debris is present in the filter then the pipework and con trol should be thoroughly cleaned before re assembly Remove the burner unit as in relevant section and pil...

Страница 13: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Страница 14: ...e appliance is installed the chimney should be swept All flues should be checked by the installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This a...

Страница 15: ...control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the knob in this...

Страница 16: ...lot is extinguished during use of the fire you MUST wait ten minutes before repeating the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control kn...

Страница 17: ...igure 11 Care should be taken to ensure that the coals bridge the gap between the front coal and the four coal supports at the front of the matrix Care should also be taken not to push the coals right...

Страница 18: ...oals or change them for a different type Never throw rubbish or other matter onto the coal bed 1 Refer back to section 6 0 Fuel bed layout coal effect and follow steps 1 and 2 The front strip and fuel...

Страница 19: ...ld be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUS...

Страница 20: ...em Part number Pack of 16 coals F550038 Pack of 16 pebbles F550050 Pack of 9 ceramic logs F550084 Front ceramic strip coal F780008 Front ceramic strip pebble F780017 Front ceramic strip Log F780050 Ce...

Страница 21: ...GI Gas Safe registered installer evidence of which must be provided such as the receipt Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheek...

Отзывы: