• This appliance is an Inset Decorative Fuel Effect appliance which provides radiant warmth utilising the latest type burner technology.
• The fire is designed to suit various types of fireplaces and natural draught flues as detailed in this manual.
• The appliance must be installed by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998. It is
strongly recommended that a GAS SAFE registered engineer be used for this purpose.
• Read all these instructions before commencing installation.
• This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space.
• The appliance is designed for installation on to a non-combustible hearth of at least 300mm depth.
• This appliance is factory set for operation on the gas type, and at the pressure stated on the appliance data plate.
• In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve.
• The appliance must be installed in accordance with the following:

• Failure to comply with the above could lead to prosecution and deem the manufacturer’s warranty invalid.
• The appliance is designed to fit various types of situations as described in sections 3.0 and 4.0.
• It should be noted that heaters create warm air currents.  These currents move heat to wall surfaces next to the heater. Installing the
heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air (such as tobacco smoke, candle smoke
etc.) exist, may cause the walls to become discoloured.
• WARNING: The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob
and ash pan door. 

• As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the elder-

ly or infirm.

• Consult ALL instructions before installation and use of this appliance. 
• This appliance is free from any asbestos material. 
• Refractories and fuel bed are constructed from ceramic fibre.

• Slide control models : These appliances feature a battery-operated control system, and under normal usage will need a new battery

approximately every twelve months.

Burner/spark generator requirements - 1 x AA (1.5 volt)

Refer to the appropriate section of these instructions for details of how to change the battery.

• Remote control models : This appliance features a battery-operated remote control system, and under normal usage will need

new batteries approximately every twelve months.

Remote control Handset requirements - 1 x ‘PP3’ type (9 volt)

Receiver/motor unit  requirements - 4 x ‘AA’ type (1.5 volt) 

Refer to the appropriate section of these instructions for details of how to change the batteries.

I N S T A L L A T I O N   I N S T R U C T I O N S

2

GB IE

• Manufacturers' Instructions.
• The Building Regulations issued by the Department for Communities and Local Government, the Building Standards (Scotland)   

(Consolidation) Regulations issued by the Scottish Development Department.

• Relevant British Standards insofar as the relevant areas are not covered by these instructions.
• For Republic of Ireland, reference should be made to the current edition of IS813 (the relevant standards governing installation).

Section

1.0

2.0

3.0

4.0

4.1

5.0

6.0

7.0

7.1

8.0

9.0

10.0

11.0

11.1

11.2

11.3

11.4

Contents

Important Notes

Appliance Data

Installation Requirements

Site Requirements

Debris Collection Space

Ventilation

Pre Fabricated Flue Boxes

Unpacking the Appliance

Component Checklist

Preparing the Appliance 

Preparing the Opening

Gas Supply Routing

Fitting the Firebox

Installation by Cable Fixing Kit

Gas Connection

Fuel Bed Layout

Fitting the Firefront / Frame

Page No.

2

3

3

3

4

5

5

5

5

6

7

7

7

8

8

8

8

Section

12.0

12.1

12.2

12.3

12.4

12.5

12.6

12.7

12.8

13.0

13.1

13.2

13.3

13.4

13.5

13.6

13.7

14.0

Contents

Testing and Commissioning

Operating the Fire (Manual control)

Operating the Fire (Slide control)

Operating the Fire (Remote control)

Spark Gap

Operating  Pressure - 

manual, slide & remote controls

Flue Spillage Monitoring System

Testing for Spillage

Briefing the customer

Servicing

Cleaning the ceramics

Removing the burner

Servicing the burner

Pilot assembly

Removing the firebox

Replacing the batteries-

Remote controls

Replacing the batteries-

Slide controls

Troubleshooting Guide

Page No.

8

9

9

9

10

10

10

11

11

11

12

12

12

12

12

12

12

13

1.0 IMPORTANT NOTES

© 2013 Focal Point Fires plc.

Содержание ALVOR FULL DEPTH RADIANT

Страница 1: ...ekeeping Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt...

Страница 2: ...and under normal usage will need a new battery approximately every twelve months Burner spark generator requirements 1 x AA 1 5 volt Refer to the appropriate section of these instructions for details...

Страница 3: ...rom dam aging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and ter minals These appliances have been tested for use with...

Страница 4: ...may be fixed to the wall above the fire providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible ma...

Страница 5: ...ox does not obscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements...

Страница 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use...

Страница 7: ...siliconed When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet...

Страница 8: ...suitable gas route can be achieved Purge the gas supply thoroughly to remove air and dirt debris before connection Disconnect the inlet restrictor elbow from the inlet pipe Connect the previously inst...

Страница 9: ...mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the ceramic fuel bed When cold the coals or...

Страница 10: ...the HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in section 2 0 of these instructions The fire is factory set to achieve these pressures a...

Страница 11: ...ded during this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in...

Страница 12: ...t must be used If a large amount of debris is present in the filter then the pipework and con trol should be thoroughly cleaned before re assembly Remove the burner unit as in relevant section and pil...

Страница 13: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Страница 14: ...e appliance is installed the chimney should be swept All flues should be checked by the installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This a...

Страница 15: ...control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the knob in this...

Страница 16: ...lot is extinguished during use of the fire you MUST wait ten minutes before repeating the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control kn...

Страница 17: ...igure 11 Care should be taken to ensure that the coals bridge the gap between the front coal and the four coal supports at the front of the matrix Care should also be taken not to push the coals right...

Страница 18: ...oals or change them for a different type Never throw rubbish or other matter onto the coal bed 1 Refer back to section 6 0 Fuel bed layout coal effect and follow steps 1 and 2 The front strip and fuel...

Страница 19: ...ld be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUS...

Страница 20: ...em Part number Pack of 16 coals F550038 Pack of 16 pebbles F550050 Pack of 9 ceramic logs F550084 Front ceramic strip coal F780008 Front ceramic strip pebble F780017 Front ceramic strip Log F780050 Ce...

Страница 21: ...GI Gas Safe registered installer evidence of which must be provided such as the receipt Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheek...

Отзывы: