•  The  installation  and  Servicing  of  this  fire  MUST  only  be  carried  out  by  a  competent  person  in  accordance  with  local  Codes  and/or

Regulations, Building Regulations and the manufacturer's instructions. Failure to comply with these could lead to prosecution and invalidate

the appliance warranty. In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve. This

appliance is only suitable for the gas type for which it is supplied.

• Keep a note of the installer's name and address, the original purchase receipt and the date of installation. Failure to produce this informa-

tion may invalidate the warranty. The appliance should be serviced regularly to ensure continued safe operation.  See the servicing section

for further reference. Frequency of service will depend on use, but MUST be carried out at least once annually.

• Parts of this appliance become naturally hot during use.  The manufacturer of this appliance considers all surfaces as working surfaces with

the exception of the control knob and control panel. 

• As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the elderly or

infirm.

• The appliance should be serviced regularly to ensure continued safe operation. Frequency of service will depend on use, but MUST be car-

ried out at least once annually.

• Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl or embossed paper), low temperature sur-

rounds etc may discolour if fitted too close to the fire. See relevant section for further details on clearances to combustibles. No combustible

materials or flooring should protrude onto the hearth.

• This appliance incorporates a combustion monitoring system (ODS).

• DO NOT burn any foreign material on this fire, the ceramic fuel effect components must be of the correct type and laid out in accordance

with the relevant section of these instructions. 

• Failure to do so could create a hazard or lead to sooting.

• Before the appliance is installed, the chimney should be swept. All flues should be checked by the installer to ensure there are no defects

or obstructions that may prevent the flow of combustion products.

• This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur. It is NOT a sub-

stitute for an independently mounted Carbon Monoxide detector.

•  This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow under the firebed for the cor-

rect functioning of this appliance. Use ONLY the firefront supplied with the appliance. Use of any other firefront could be dangerous.

U S E R     I N S T R U C T I O N S

2.0 CLEARANCES TO COMBUSTIBLES

A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.

A non-combustible shelf may be fitted to within 10mm of the top edge of the fireplace opening. Combustible materials, such as wood, may be

fitted to within 100mm of either side of the fireplace opening, providing the forward projection does not exceed 100mm.

Any combustible side walls must be at least 500mm to the side of the radiant heat source. As with all heating appliances, any decorations, soft

furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch.

1.0 IMPORTANT NOTES

1

GB IE

© 2013 Focal Point Fires plc.

Maximum depth of shelf    

Minimum distance from finished hearth surface to underside of shelf

100mm

745mm

150mm

845mm

203mm

895mm

Section

1.0

2.0

3.0

4.0

5.0

5.1

5.2

6.0

7.0

Contents

Important Notes

Clearances to Combustibles

Fireguards

Ventilation

Operating Instructions - manual control

Operating Instructions - slide control

Operating Instructions - remote control

Flue Spillage Monitoring System

Fuel Bed Layout - coal effect

Page No.

1

1

2

2

2

3

3

3

4

Section

7.1

8.0

9.0

10.0

10.1

11.0

12.0

13.0

14.0

Contents

Fuel Bed Layout - pebble effect

Servicing

Cleaning

Replacing the batteries-

Remote controls

Replacing the batteries-

Slide controls

List of replacement parts

Installation details

Service History

Guarantee - Terms and Conditions

Page No.

5

6

6

7

7

7

7

8

8

Содержание ALVOR FULL DEPTH RADIANT

Страница 1: ...ekeeping Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt...

Страница 2: ...and under normal usage will need a new battery approximately every twelve months Burner spark generator requirements 1 x AA 1 5 volt Refer to the appropriate section of these instructions for details...

Страница 3: ...rom dam aging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and ter minals These appliances have been tested for use with...

Страница 4: ...may be fixed to the wall above the fire providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible ma...

Страница 5: ...ox does not obscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements...

Страница 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use...

Страница 7: ...siliconed When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet...

Страница 8: ...suitable gas route can be achieved Purge the gas supply thoroughly to remove air and dirt debris before connection Disconnect the inlet restrictor elbow from the inlet pipe Connect the previously inst...

Страница 9: ...mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the ceramic fuel bed When cold the coals or...

Страница 10: ...the HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in section 2 0 of these instructions The fire is factory set to achieve these pressures a...

Страница 11: ...ded during this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in...

Страница 12: ...t must be used If a large amount of debris is present in the filter then the pipework and con trol should be thoroughly cleaned before re assembly Remove the burner unit as in relevant section and pil...

Страница 13: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Страница 14: ...e appliance is installed the chimney should be swept All flues should be checked by the installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This a...

Страница 15: ...control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the knob in this...

Страница 16: ...lot is extinguished during use of the fire you MUST wait ten minutes before repeating the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control kn...

Страница 17: ...igure 11 Care should be taken to ensure that the coals bridge the gap between the front coal and the four coal supports at the front of the matrix Care should also be taken not to push the coals right...

Страница 18: ...oals or change them for a different type Never throw rubbish or other matter onto the coal bed 1 Refer back to section 6 0 Fuel bed layout coal effect and follow steps 1 and 2 The front strip and fuel...

Страница 19: ...ld be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUS...

Страница 20: ...em Part number Pack of 16 coals F550038 Pack of 16 pebbles F550050 Pack of 9 ceramic logs F550084 Front ceramic strip coal F780008 Front ceramic strip pebble F780017 Front ceramic strip Log F780050 Ce...

Страница 21: ...GI Gas Safe registered installer evidence of which must be provided such as the receipt Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheek...

Отзывы: