Operating Instructions EMGZ492.PNET
05.10.2018
24
0x02
Offset A
Access
type
R/W
Parameter command
offset
Data type
int (unsigned 16 bit)
Value
range
-16‘000
to
16‘000
Value format
±#####
0x03
Gain A
Access
type
R/W
Parameter command
gain
Data type
int (unsigned 16 bit)
Value range
100 to 20‘000
Value format
##.###
0x04
Nominal force A
The nominal force is the maximum permissible force of
the used measuring system.
Access
type
R/W
Parameter command
Nominal force
Data type
long (unsigned 32 bit)
Value range
0 to 200‘000‘000
Value format
######.###
Unit
N
0x05
Low-pass filter active A
Switch the low-pass filter actual value on or off; 0 = off; 1
= on.
Not remanent: The adjusted value is lost on a restart! This
filter is switched on after a restart.
This parameter cannot be accessed via the web interface.
Access
type
R/W
Parameter command
low-pass filter actual value
active (PROFINET)
Data type
byte (unsigned 8 bit)
Value range
0 to 1
Value format
#