Operating Manual EMGZ309._.EIP
31
Language
LCD:
Language
Use:
This parameter determines the displayed language. The user can
choose between the two languages: English and German. The menu
navigation in the web browser is always in English.
Unit
Parameter Range
Selection
Default
Min
Max
-
-
-
English
German
English
LCD-Contrast
LCD:
Contrast.
Use:
The parameter [Contrast] changes the contrast of the LCD to achieve
optimal readability.
Unit
Parameter Range
Selection
Default
Min
Max
%
1
100
-
65
Ethernet-Interface
LCD:
Ethernet
Use:
The Ethernet interface of EMGZ309 can be switched on and off with this
parameter. The deactivation of this interface reduces the power
consumption by 25% and lowers heat generation in the device
considerably. FMS recommends to activated the Ethernet interface only
when needed..
Unit
Parameter Range
Selection
Default
Min
Max
-
-
-
On
Off
On
Ethernet IP Address
LCD:
IP Addr.
Use:
The parameter assigns an IP address to the amplifier. This enables the
user to communicate via a web browser with the amplifier that is
imbedded in a network. The IP address must be entered in 4 separate
blocks (IP Bl. 1; IP Bl. 2; IP Bl. 3; and IP Bl. 4)
Unit
Parameter Range
Selection
Default
Min
Max
-
000.000
000.000
255.255.
255.255
-
192.168
000.090