TO TURN OFF GAS
TO APPLIANCE
1. Set ON/OFF switch located on rear cover
to OFF.
2a. Open lower panel.
2b.
If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to the appli-
ance if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Close lower panel.
6. Close equipment shutoff valve (see Figure
31, page 21).
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see
Removing/Re-
placing Glass Door
, page 23).
2. Follow steps 1 through 8 under
Lighting
Instructions
, page 26.
3. Press control knob and light pilot with
match.
4. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 10 through 13 of
Lighting
Instructions
, page 26.
5. Replace glass door (see
Removing/Re-
placing Glass Door
, page 23).
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 35). Follow instructions included with
the remote control.
NOTICE: you must light the pilot
before using the hand-held re
-
mote control unit. See
Lighting
Instructions
, page 30.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON position.
Adjust flame adjustment knob anywhere be
-
tween HI and LO. Slide the selector switch to
the REMOTE position (see Figure 45).
Note: The burner may light if hand-held re-
mote was on when selector switch was last
oPeration
Continued
turned off. You can now turn the burner on and
off with the hand-held remote control unit.
IMPORTANT:
Do not leave the selector switch
in the REMOTE or ON position when the pilot
is not lit. This will drain the battery.
Figure 45 - Setting the Selector Switch,
Control Knob, and Flame Adjustment
Knob for Remote Operation
HI
LO
IN
OUT
Selector Switch in Remote
Position (Optional Remote
Control)
Control Knob
in On Position
OPERATING OPTIONAL
GWMT1 WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a fire hazard will occur.
Light the burner system as instructed in
Lighting Instructions
on page 30. Set wall
thermostat to desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust
-
ment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
To turn the burner system off, adjust ther
-
mostat to the lowest setting and turn the gas
control knob back to PILOT. The pilot will
remain lit.
IMPORTANT:
To turn the pilot off, turn the
control knob on the heater to the OFF posi-
tion.