background image

2

106424

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

DVF34, DVF34P

SAFETY
INFORMATION

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit
is used.

2.

For propane/LP fireplace, do not place
propane/LP supply tank(s) inside any
structure. Locate propane/LP supply
tank(s) outdoors. To prevent perfor-
mance problems, do not use propane/LP
fuel tank of less than 100 lbs. capacity.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier's instructions

• if you cannot reach you gas supplier,

call the fire department.

4.

Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42" from the front, top, or sides of
the fireplace

• in high traffic areas
• in windy or drafty areas

5.

This fireplace reaches high tempera-
tures. Keep children and adults away
from hot surfaces to avoid burns or
clothing ignition. Fireplace will remain
hot for a time after shutdown. Allow sur-
faces to cool before touching.

6.

Carefully supervise young children
when they are in the room with fireplace.

7.

Do not modify this fireplace under any
circumstances. Any parts removed for
servicing must be replaced prior to op-
erating fireplace.

8.

Turn fireplace off and let cool before
servicing, installing, or repairing. Only
a qualified service person should in-
stall, service, or repair this fireplace.
Have fireplace inspected annually by a
qualified service person.

9.

You must keep control compartments,
burners, and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, etc.
Turn off the gas valve and pilot light
before cleaning fireplace.

10. Have venting system inspected annu-

ally by a qualified service person. If
needed, have venting system cleaned
or repaired. See Cleaning and Mainte-
nance
, page 26.

11. Keep the area around your fireplace

clear of combustible materials, gaso-
line, and other flammable vapor and
liquids. Do not run fireplace where
these are used or stored. Do not place
items such as clothing or decorations
on or around fireplace.

12. Do not use this fireplace to cook food

or burn paper or other objects.

13. Do not use any solid fuels (wood, coal,

paper, cardboard, etc.) in this fireplace.
Use only the gas type indicated on fire-
place nameplate.

14. This appliance, when installed, must be

electrically grounded in accordance
with local codes or, in the absence of
local codes, with the National Electri-
cal Code, ANS/NFPA 70
, or the Cana-
dian Electrical Code, CSA C22.1
.

15. Do not obstruct the flow of combus-

tion and ventilation air in any way. Pro-
vide adequate clearances around air
openings into the combustion chamber
along with adequate accessibility clear-
ance for servicing and proper operation.

16. Do not install fireplace directly on car-

peting, vinyl tile, or any combustible
material other than wood. The fireplace
must set on a metal or wood panel ex-
tending the full width and depth of the
fireplace.

17. Do not use fireplace if any part has been

exposed to or under water. Immediately
call a qualified service person to ar-
range for replacement of the unit.

18. Do not operate fireplace if any log is

broken.

19. Do not use a blower insert, heat ex-

changer insert, or other accessory not
approved for use with this fireplace.

20. Do not operate fireplace with glass door

removed, cracked, or broken.

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this fireplace. Im-
proper use of this fireplace can
cause serious injury or death from
burns, fire, explosions, electrical
shock, and carbon monoxide
poisoning.

 WARNING: Any change to

this fireplace or its controls can
be dangerous.

 WARNINGS

 DANGER: Carbon monoxide

poisoning may lead to death!

This fireplace is a vented product. This
fireplace will not produce any gas leakage
into your home if properly installed. This
fireplace must be properly installed by a
qualified service person. The glass door
must be properly seated and sealed. If this
unit is not properly installed by a qualified
service person with glass door properly
seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not
have been installed properly. Get fresh air
at once!
 Have fireplace inspected and ser-
viced by a qualified service person. Some
people are more affected by carbon monox-
ide than others. These include pregnant
women, people with heart or lung disease or
anemia, those under the influence of alcohol,
and those at high altitudes.

Propane/LP gas and natural gas are both
odorless. An odor-making agent is added to
each of these gases. The odor helps you
detect a gas leak. However, the odor added
to these gases can fade. Gas may be present
even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.

Содержание DVF34

Страница 1: ...assis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by s...

Страница 2: ...cated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS NFPA...

Страница 3: ...piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 FMI Direct Vent Fireplace DVF Series Glass Door Assembly Blower Adjustment Optional Installation...

Страница 4: ...for drywall facing Must maintain a minimum 1 clearance to combustibles 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace...

Страница 5: ...mbustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding If exterior wall is vinyl you must use a vinyl si...

Страница 6: ...to a mechanical air supply inlet 72 inches 1829mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck...

Страница 7: ...ermination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount...

Страница 8: ...pipes and fittings have spe cial twist lock connections Assemble the desired combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Pro...

Страница 9: ...or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13...

Страница 10: ...cal pipe 90 elbow 67 min 60 max 79 min 84 max 96 min 20 max Note This configuration for use with corner installation Horizontal Termination Configurations Figures 16 through 19 show different con figu...

Страница 11: ...ax 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 18 Horizontal Termination Configuration for Rigid Ve...

Страница 12: ...bers Note Pay special attention to these installation instruc tions for required clearances air space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack...

Страница 13: ...support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold the resulting flaps over the roof shea...

Страница 14: ...TING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 26 Vertical Rigid Venting...

Страница 15: ...NENTS FMI Rigid Venting Number Description FD30 30 Starter Adapter 65 8 to7 6 per box FD60 60 Starter Adaptor 65 8 to7 6 per box F7030 7 to 12 Adjustable pipe length 6 per box D1031 7 to 12 Adjustable...

Страница 16: ...n system s circulating blower while using fireplace This will help circulate the heat through out the house In the event of a power outage you can use this fireplace as a heat source WARNING A qualifi...

Страница 17: ...ee Figure 32 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is recess...

Страница 18: ...able alternative to test gauge connection Pur chase the CSA design certified equipment shutoff valve from your retailer WARNING A qualified ser vice person must connect fire place to gas supply Follow...

Страница 19: ...ected fittings for leaks CHECKING GAS CONNECTIONS WARNING Test all gas pip ing and connections for leaks after installing or servicing Cor rect all leaks at once WARNING Neveruseanopen flame to check...

Страница 20: ...valve see Fig ure 36 2 Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in...

Страница 21: ...MS2 includes 25 of wire for installation Your fireplace includes 15 of wire for accessoryinstallation Choosethe length that best fits your needs when installing this accessory 1 Connect one terminal o...

Страница 22: ...e method described in step 3 6 Slide the right retainer bracket against the right side brick panel Loosely se cure the bracket screw This secures the right side brick panel 7 Install rear brick panel...

Страница 23: ...the front right part of the grate making sure the notches fit over the prong of the grate see Figure 49 6 Place lava rock along sides and front of inside of firebox bottom It is not necessary to use a...

Страница 24: ...urn gas control knob counterclock wise to PILOT 9 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until a flame appears Cont...

Страница 25: ...ce off see To Turn Off Gas to Appliance page 24 see Troubleshooting pages 27 through 29 Figure 53 Pilot Assembly Thermocouple Thermopile 3 8 to 1 2 1 8 Pilot Burner Piezo Ignitor Figure 52 Setting the...

Страница 26: ...urn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire...

Страница 27: ...valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the mounting bra...

Страница 28: ...r until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 26 or replace burner orifice 1 Adjust the log set s...

Страница 29: ...2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas od...

Страница 30: ...connection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Note Use only original replacement parts Thiswillprotectyourwarranty...

Страница 31: ...upply Pressure 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges or 817 x 873...

Страница 32: ...P DVF34 DVF34P 47 1 2 3 4 6 6 35 5 5 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31 1 31 4 31 2 31 3 33 32 32 34 46 36 37 39 38 42 40 41 6...

Страница 33: ...Pilot Propane LP 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Piezo Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 0...

Страница 34: ...before installing on fireplace BRICK LINER D8037A Not Shown This brick liner adds a touch of style to your direct ventfireplaceandcomeswitheasyto follow instructions for installation ON OFF WALL MOUN...

Страница 35: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 36: ...pairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRES...

Отзывы: