OPERATING
FIREPLACE

Continued

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening
the lower louver panel on the fireplace.
Blower controls are located on the left
side of the switch bracket to the left just
inside the louver panel.

Both the GA3700 manual blower and the
DA3610TA thermostatically-controlled
blower have an ON setting and an OFF
setting. The blower will only run when the
switch is in the ON position. In the OFF
position, the blower will not operate.

Note for DA3610TA Only:

 If you are

using DA3610TA blower, your fireplace
and blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on. After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.

The blower helps distribute heated air
from the fireplace. Periodically check the
louvers of the firebox and remove any
dust, dirt, or other obstructions that will
hinder the flow of air.

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the
proper flame height. Alterations may have
occurred during shipping and handling. Call
a qualified service person to readjust the
pilot if necessary.

The height of the thermopile must be 3/8" to
1/2" above the pilot flame as shown in Figure
53. The thermocouple must be at a height of
about 1/8" above the pilot flame. The flame
from the pilot burner must extend beyond
both the thermocouple and thermopile.

If your pilot assembly does not meet these
requirements:

• turn fireplace off (see To Turn Off Gas to

Appliance, page 24)

• see Troubleshooting, pages 27 through 29

Figure 53 - Pilot Assembly

Thermocouple

Thermopile

3/8" to 1/2"

1/8"

Pilot Burner

Piezo
Ignitor

Figure 52 - Setting  the Selector Switch,
Gas Control Knob, and Variable Control
Knob for Remote Operation

Selector Switch in
Remote Position

Gas Control
Knob in On
Position

Variable
Control Knob

Blower Control Knob
(Optional Accessory)

OPERATING

OPTIONAL HAND-

HELD REMOTE

1.

After lighting, let pilot flame burn for
about one minute. Turn gas control
knob on the control valve to ON posi-
tion. Turn variable control knob any-
where between HI and LO. Slide the
selector switch to the REMOTE po-
sition. 

Note: 

The burners may light if

hand-held remote ON button was on
when selector switch was last turned
off. You can now turn the burners on
and off with the hand-held remote con-
trol unit.

IMPORTANT:

 Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

 Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

2.

Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.

IMPORTANT:

 To turn the pilot off,

manually turn the gas control knob
on the heater to the OFF position.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions, page 24.

OPERATING

OPTIONAL GWMS2

WALL MOUNTED

SWITCH

Make sure the heater switch is on AUTO.
This wall switch works just like the con-
ventional light switch. Flip the switch up
for on and down for off.

Note:

 Make sure that this switch is not in

a position to be mistaken for a light switch.
This may result in the heater being inad-
vertently turned on without the proper
precautions being taken. See installation
instructions on page 21 of this manual.

Continued

Содержание DVF34

Страница 1: ...assis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by s...

Страница 2: ...cated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS NFPA...

Страница 3: ...piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 FMI Direct Vent Fireplace DVF Series Glass Door Assembly Blower Adjustment Optional Installation...

Страница 4: ...for drywall facing Must maintain a minimum 1 clearance to combustibles 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace...

Страница 5: ...mbustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding If exterior wall is vinyl you must use a vinyl si...

Страница 6: ...to a mechanical air supply inlet 72 inches 1829mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck...

Страница 7: ...ermination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount...

Страница 8: ...pipes and fittings have spe cial twist lock connections Assemble the desired combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Pro...

Страница 9: ...or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13...

Страница 10: ...cal pipe 90 elbow 67 min 60 max 79 min 84 max 96 min 20 max Note This configuration for use with corner installation Horizontal Termination Configurations Figures 16 through 19 show different con figu...

Страница 11: ...ax 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 18 Horizontal Termination Configuration for Rigid Ve...

Страница 12: ...bers Note Pay special attention to these installation instruc tions for required clearances air space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack...

Страница 13: ...support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold the resulting flaps over the roof shea...

Страница 14: ...TING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 26 Vertical Rigid Venting...

Страница 15: ...NENTS FMI Rigid Venting Number Description FD30 30 Starter Adapter 65 8 to7 6 per box FD60 60 Starter Adaptor 65 8 to7 6 per box F7030 7 to 12 Adjustable pipe length 6 per box D1031 7 to 12 Adjustable...

Страница 16: ...n system s circulating blower while using fireplace This will help circulate the heat through out the house In the event of a power outage you can use this fireplace as a heat source WARNING A qualifi...

Страница 17: ...ee Figure 32 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is recess...

Страница 18: ...able alternative to test gauge connection Pur chase the CSA design certified equipment shutoff valve from your retailer WARNING A qualified ser vice person must connect fire place to gas supply Follow...

Страница 19: ...ected fittings for leaks CHECKING GAS CONNECTIONS WARNING Test all gas pip ing and connections for leaks after installing or servicing Cor rect all leaks at once WARNING Neveruseanopen flame to check...

Страница 20: ...valve see Fig ure 36 2 Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in...

Страница 21: ...MS2 includes 25 of wire for installation Your fireplace includes 15 of wire for accessoryinstallation Choosethe length that best fits your needs when installing this accessory 1 Connect one terminal o...

Страница 22: ...e method described in step 3 6 Slide the right retainer bracket against the right side brick panel Loosely se cure the bracket screw This secures the right side brick panel 7 Install rear brick panel...

Страница 23: ...the front right part of the grate making sure the notches fit over the prong of the grate see Figure 49 6 Place lava rock along sides and front of inside of firebox bottom It is not necessary to use a...

Страница 24: ...urn gas control knob counterclock wise to PILOT 9 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until a flame appears Cont...

Страница 25: ...ce off see To Turn Off Gas to Appliance page 24 see Troubleshooting pages 27 through 29 Figure 53 Pilot Assembly Thermocouple Thermopile 3 8 to 1 2 1 8 Pilot Burner Piezo Ignitor Figure 52 Setting the...

Страница 26: ...urn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire...

Страница 27: ...valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the mounting bra...

Страница 28: ...r until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 26 or replace burner orifice 1 Adjust the log set s...

Страница 29: ...2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas od...

Страница 30: ...connection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Note Use only original replacement parts Thiswillprotectyourwarranty...

Страница 31: ...upply Pressure 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges or 817 x 873...

Страница 32: ...P DVF34 DVF34P 47 1 2 3 4 6 6 35 5 5 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31 1 31 4 31 2 31 3 33 32 32 34 46 36 37 39 38 42 40 41 6...

Страница 33: ...Pilot Propane LP 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Piezo Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 0...

Страница 34: ...before installing on fireplace BRICK LINER D8037A Not Shown This brick liner adds a touch of style to your direct ventfireplaceandcomeswitheasyto follow instructions for installation ON OFF WALL MOUN...

Страница 35: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 36: ...pairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRES...

Отзывы: