OWNER’S MANUAL
29"
13"
12
5
/
8
"
34
3
/
8
"
35
1
/
16
"
58"
9
1
/
4
"
41"
Nailing Tabs
PRE-INSTALLATION
PREPARATION
Continued
Figure 6 - Framing Clearances for Corner Installation
LOCATION OF VENT
TERMINATION
When locating vent termination, it is impor-
tant to observe the minimum clearances
shown in Figure 8, page 6. You will avoid
extra framing by positioning your fireplace
against an already existing framing mem-
ber. The sides of the fireplace may be posi-
tioned directly against combustible walls.
*Check with local codes or with the current
CAN/CGA B149 [.1 or .2] Installation Codes
for Canada or the USA Installations follow
the current National Fuel Gas Code, ANS
Z223.1, also known as NFPA 54.
These models are approved for use with
FMI 7" direct-vent pipe components and
terminations.
Your fireplace is approved to be vented either
through the side wall, or vertically using the
following guidelines:
• Only use FMI venting components or kits
specifically approved for this fireplace.
• Minimum clearance between vent pipes
and combustible materials is 1" (25 mm),
except where stated otherwise.
• Combustible material may be flush with
the top front of fireplace with a maxi-
mum thickness of 3/4".
• Do not recess venting terminals into a
wall or siding.
• If exterior wall is vinyl, you must use a
vinyl siding standoff.
• Install horizontal venting with a 1/4" rise
for every 12" of run toward the termination.
• You may paint the vent terminal with
450ºF (232ºC) heat-resistant paint to co-
ordinate with the exterior finish.
• There must not be any obstruction such
as bushes, garden sheds, fences, decks,
or utility buildings within 24" from the
front of the termination cap.
• Do not locate termination cap where exces-
sive snow or ice build up may occur. Be sure
to clear vent termination area after snow falls
to prevent accidental blockage of venting
system. When using snow blowers, do not
direct snow towards vent termination area.
GENERAL VENTING
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Figure 7 - Clearances for Combustible Mantels
Ref.
Mantel Depth
Ref. Mantel from Top
of Louver Opening
1
14" (356mm)
A
16" (406mm)
2
12" (305mm)
B
14" (356mm)
3
10" (254mm)
C
12" (305mm)
4
8" (203mm)
D
10" (254mm)
5
6" (152mm)
E
8" (203mm)
6
4" (101mm)
F
6" (152mm)
7
2" (51mm)
G
4" (101mm)
Continued
Note: There must be
a minimum clear-
ance of 18" above
top of louver
opening when
installing a television
or entertainment
center above the
fireplace.