background image

www.fmiproducts.com

125206-01B

24

FIREPLACE INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD 

REMOTE CONTROL INSTALLATION

Note:  If  using  an  optional  wireless  hand-

held remote control, wall switch is no longer 

operational.

INSTALLING OPTIONAL WIRELESS 

HAND-HELD REMOTE CONTROL 

MRC SERIES

NOTICE: Use only alkaline bat

-

teries (not included).

Installing Remote Receiver

1.  Open bottom louver and locate switch 

bracket on the right.

2.  Remote receiver can be placed in the hole 

on the switch bracket or placed on the 

floor underneath the firebox, see Figure 

37. See remote instructions for further 

information.

3.  Attach terminal wires to battery.
4.  Connect wires from receiver to TH and 

TPTH to control valve (see Figure 38).

GAS LINE HOOK-UP

 WARNING: Before you pro

-

ceed, make sure your gas supply 

is OFF.

 WARNING: Gas line hookup 

should  be  done  by  your  gas 

supplier  or  a  qualified  service 

person.

An equipment shutoff valve has been included 

in the appliance’s gas supply system. You may 

consider installing an extra gas shutoff valve 

outside appliance’s enclosure (check with 

local codes) where it can be accessed more 

conveniently with a key through a wall (see 

Figure 39, page 25).
Route a 1/2" NPT black iron gas line towards 

appliance coming in from the left. It is rec-

ommended to route pipe between stand of 

firebox and surround of fireplace (see Figure 

40, page 25).

IMPORTANT: 

The appliance and its individual 

shutoff valve must be disconnected from the 

gas supply piping system during any pressure 

testing of 1/2 psig. (3.5 kPa). The appliance 

must be isolated from the gas supply piping 

system by closing its individual equipment 

shutoff valve during any pressure testing of 

the gas supply piping system at test pressure 

equal to or less than 1/2 psig. (3.5 kPa).

Figure 37 - Remote Receiver

Figure 38 - Control Valve Terminals

To Optional 

Remote 

Accessory

To Wall
Thermostat

Wire terminals

Remote Receiver

Receiver

Slide

Button

REMOTE

OFF

ON

LEARN

ADJ.

 

f i r e - p a r t s . c o m

Содержание DVF32TMHPN-LS

Страница 1: ...ctrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Страница 2: ...the rating plate A conversion kit is supplied with the fireplace State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts SAVE THI...

Страница 3: ...of any component part not manufac tured or approved byFMI PRODUCTS LLC in combination with a FMI PRODUCTS LLC fireplace system Proper installation is the most important step in ensuring safe and cont...

Страница 4: ...tural and propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor ex...

Страница 5: ...fireplace in windy or drafty areas where curtains or other combustible flammable objects can make contact with the fireplace front in high traffic areas 4 Turn fireplace off and let cool before servi...

Страница 6: ...34 3 4 3 BACK VIEW TOP VIEW Left Side Right Side Front Back 24 1115 16 101 2 11 2 11 2 101 2 FRONT VIEW 30 Opening 24 25 RIGHT SIDE 22 5 8 43 1 8 32 Opening 1 7 8 1 7 8 BACK VIEW 39 3 4 26 3 8 3 1 2 3...

Страница 7: ...TS Determine the safest and most efficient loca tion for your FMI PRODUCTS LLC direct vent fireplace Make sure that rafters and wall studs are not in the way of the venting system Choose a location wh...

Страница 8: ...e 5 Minimum Clearances See Thru Shown Combustible Material Drywall 2 x 4 Stud Minimum 1 Clearance from Side Only for See Thru FRAMING Once final location has been determined observing clearances for v...

Страница 9: ...quare Min Figure 12 Rough Opening for Installing Exterior Vent Terminal Vertical Height Depends on Installation 26 3 8 Horizontal Length Depends on Installation 90o Elbow 45o Elbow Figure 13 Vent Open...

Страница 10: ...n line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEA...

Страница 11: ...al codes In the USA follow the current National Fuel Gas Fuel Gas Code ANS Z223 1 also known as NFPA 54 These models are approved for use with FMI PRODUCTS LLC Series rigid type direct vent pipe as su...

Страница 12: ...greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clear...

Страница 13: ...ce from fireplace flue outlet to ceiling Add ceiling thickness vertical rise in an attic or second story and allow for sufficient vent height above roof line You may use one or two 90 elbows in this v...

Страница 14: ...des Note When installing in a chase you should insulate the chase as you would the outside walls of your home This is especially im portant in cold climates Minimum clearance between vent pipes and co...

Страница 15: ...bustible exterior wall 8 1 2 diameter hole if non combustible Frame as necessary Figure 17 Vent Pipe Connections Male Slots Female Locking Lugs Rigid Vent Pipe 4 Three types of vent caps are available...

Страница 16: ...unit is tight and does not come loose before unit is nailed to framing Square vent or long vent configuration Vent pipe must be manipulated at outer end to make final connection Manually secure pipe...

Страница 17: ...t to be used with a vertical termination 1 Determine route your vertical venting will take If ceiling joists roof rafters or other framing will obstruct venting system consider an offset see Figure 24...

Страница 18: ...er the same size as ceiling joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clearance space If ar...

Страница 19: ...vent pipe passes through any oc cupied areas above the first floor including storage spaces and closets you must enclose pipe You may frame and sheetrock enclosure with standard construction material...

Страница 20: ...Configuration Using Two 90 Elbows VENTING INSTALLATION Continued Vertical Termination Configurations Figures 29 through 32 show four different configurations for vertical termination These minimum ve...

Страница 21: ...0 feet USA you may need to decrease the input rating by changing the existing burner orifice to a smaller size Reduce input 4 for each 1 000 feet above sea level Check with your local gas company for...

Страница 22: ...ed P58 12 12 Section Double Wall Pipe Galvanized P58 6 6 Section Double Wall Pipe Galvanized VENTING INSTALLATION Continued Number Description PA58 712 Adjustable 7 12 Section Double Wall Pipe Galvani...

Страница 23: ...within an accessible distance behind louvered opening see Figure 35 You may test blower for operation by turning control knob clockwise just until it clicks on which is the full on position Adjust fa...

Страница 24: ...person An equipment shutoff valve has been included in the appliance s gas supply system You may consider installing an extra gas shutoff valve outside appliance s enclosure check with local codes whe...

Страница 25: ...a leak is detected WARNING Improper installa tion adjustment alteration service or maintenance can cause injury or propertydamage Refertothismanu al For assistance or additional infor mation consult a...

Страница 26: ...ght twig which is placed across top of logs B 5 Figure 44 shows the top view of burner and grate 6 Place logs A as shown in Figure 45 7 Place logs B as shown in Figure 46 page 27 Lift end of log A tha...

Страница 27: ...ued PILOT ELECTRODE ASSEMBLY ADJUSTMENT The pilot assembly is factory preset for the proper flame height Alteration to these set tings may have occurred during shipping and handling If this is the cas...

Страница 28: ...r s normal setting is fully open Do not forget to retighten the air shutter screw Figure 52 Burner Removal BURNER REMOVAL CAUTION Beforeproceeding toopenglassdoororhandlelogs make sure entire unit is...

Страница 29: ...s should be alerted to the hazards of high surface tem peratures andtostayawayfrom the appliance to avoid burns or clothingignition Youngchildren should be carefully supervised when they are in the sa...

Страница 30: ...n may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIG...

Страница 31: ...e technician or gas supplier 9 Turn on all electric power to fireplace 10 Turn gas control knob counterclockwise to ON 11 This valve is equipped with a HI LO fea ture Set fireplace input as desired O...

Страница 32: ...cian replace pilot line 7 Replace control valve see Replacement Parts and Ac cessories page 34 8 Tighten thermocouple or replace 1 Check wiring connection Refer to Wiring Diagram page 33 1 Check elect...

Страница 33: ...e pilot or misaligned electrode at pilot 3 No or low gas pressure OBSERVED PROBLEM Whenignitorbuttonispressed there is no spark at pilot TROUBLESHOOTING Continued 1 Checkelectricalconnections and repl...

Страница 34: ...have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You m...

Страница 35: ...Only Black 01645 REFRACTORY PIECES Front Bottom 25854 Left Right Bottom 25856 Rear 25855 See Thru Only Rear 27374 Peninsula Only Front Bottom Left Right Bottom Rear For Peninsula and See Thru PIEZO I...

Страница 36: ...t and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material l...