background image

1

January 10, 2020

7045-910I

Installation Manual

Installation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. 

OWNER: Retain this manual for future reference. 

NOTICE: DO NOT DISCARD THIS MANUAL

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

If the information in these instructions is not 

followed exactly, a fire could result causing 

property damage, personal injury, or death.

 

 WARNING

• 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

• 

Do not over fire - If appliance or chimney connector 

glows, you are over firing. Over firing will void your 

warranty.

• 

Comply with all minimum clearances to combustibles 

as specified.  Failure to comply may cause house 

fire.

NOTE

To obtain a French translation of this manual, please contact 

your dealer or visit 

www.quadrafire.com

Pour obtenir une traduction française de ce manuel, s’il vous 

plaît contacter votre revendeur ou visitez 

www.quadrafire.com

WARNING

Fire Risk.

For use with solid wood fuel only.

Other fuels may over fire and generate 

poisonous gases (i.e. carbon monoxide).

4100I ACC WOOD INSERT

AUTOMATIC COMBUSTION 

CONTROL (ACC)

MODEL:

41I-ACC-BK

R

HOT SURFACES!

 

Glass and other surfaces are hot during 

operation AND cool down.  

WARNING

Hot glass and appliance will cause burns.

•  Do not touch glass until it is cooled

•  Use leather gloves when reloading fuel

•  NEVER allow children to touch glass

•  Keep children away

• 

CAREFULLY SUPERVISE children in same room as 

appliance.

•  Alert children and adults to hazards of high 

temperatures

• 

High temperatures may ignite clothing or other 

flammable materials.

•  Keep clothing, furniture, draperies and other 

flammable materials away.

This appliance has been retired.  

Service parts pages within have been removed.  

For replacement parts, please refer to the individual service parts 

list located on the brand websites.

Summary of Contents for 41I-ACC-BK

Page 1: ...nch translation of this manual please contact your dealer or visit www quadrafire com Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www quadra...

Page 2: ...ney 15 J Metal Heat Circulating Masonry 16 K Prefabricated Metal Chimney 16 L Ovalizing Round Stainless Steel Liners 17 M Altering The Fireplace 17 N Zero Clearance Fireplace 17 5 Appliance Set Up 18...

Page 3: ...ighted average HHV efficiency using Douglas Fir dimensional lumber and data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low a...

Page 4: ...ng appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Ris...

Page 5: ...draft should be approximately 10 inch W C Measure the W C at 6 inches 152mm above the top of the appliance after one hour of operation at each burn setting B Draft Check building codes prior to instal...

Page 6: ...2 3 4 in length 6 or 8 self drilling screws Fire Risk Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomplete c...

Page 7: ...appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this c...

Page 8: ...nd 43 1092 31 787 12 1 2 318 9 5 8 244 2 1 2 64 31 787 45 1143 51 1295 34 864 30 762 24 610 16 1 4 413 10 5 8 270 7 178 Figure 8 6 Front View with Large Cast Trim Steel Surround SP 41I CM LRG and 811...

Page 9: ...Figure 9 1 Side View with Steel Surround 5 127 4 1 8 105 15 20 7 8 530 21 1 2 546 21 1 8 537 9 1 8 232 11 3 8 289 Figure 9 2 Side View of Steel Surround with Optional 15 Degree Adapter DV 6DLR E15ADS...

Page 10: ...teel Surround 30 1 4 768 C Back Width 24 1 4 616 D Depth Steel Surround 16 1 2 419 Depth Cast Trim Steel Surround 16 1 2 419 B Clearances to Combustibles United States and Canada UL and ULC NOTE Minim...

Page 11: ...this for k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larg...

Page 12: ...y should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof Th...

Page 13: ...there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 13 1 13 2 Must h...

Page 14: ...configuration the greater the likelihood it may affect performance Chimney height may need to be increased by 2 3 per each 1000 feet above sea level It is not recommended to use offsets or elbows at...

Page 15: ...nimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Off...

Page 16: ...with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Combustible Floor Airtight Insulated Clean Out Stainless Steel Chi...

Page 17: ...Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Inspect the existing fireplace and chimney for any dam...

Page 18: ...e 4 inch flex 4 After sliding can into fireplace feed flex into cut opening to obtain outside combustion air 5 Level outer can and install appliance 6 Remove 4 bolts from both sides of the blower hous...

Page 19: ...stic Figure 19 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re i...

Page 20: ...ng and blower assembly in reverse order F Blower Cord Installation on Left Side The blower cord is shipped on the right side of the appliance You may relocate the cord so it is on the left side 5 32 A...

Page 21: ...t metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to sc...

Page 22: ...84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be us...

Page 23: ...23 January 10 2020 7045 910I 4100 Insert ACC 7 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Page 24: ...24 January 10 2020 7045 910I 4100 Insert ACC Date of Service Performed By Description of Service...

Page 25: ...25 January 10 2020 7045 910I 4100 Insert ACC B Accessory List...

Page 26: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this applianc...

Reviews: