INTRODUCTION

  WARNING:  This  product 

contains  and/or  generates 

chemicals  known  to  the  State 

of California to cause cancer or 

birth defects or other reproduc

-

tive harm.

Models DVF32TMHST-LS (with fan),  

DVF32TMHST-A2-LS (with fan and safety 

switch) and DVF32TMHPN-LS (with fan) are 

heat circulating gravity direct vent fireplaces 

with sealed combustion chamber. These 

fireplaces use millivolt gas control valve and 

millivolt ignition system.
These fireplaces are convertible with the 

standard setup as natural gas. Conversion 

may be performed by the OEM mobile home 

builder or by a qualified service person on-

site. If you are uncertain as to what gas your 

unit is equipped for, please check the rating 

plate located inside of the appliance opening 

or consult your mobile home supplier or your 

local distributor of FMI PRODUCTS, LLC.

NOTICE:  Check  local  building 

codes for area requirements be

-

fore installing this appliance.

BEFORE YOU BEGIN

Before beginning the installation of your 

appliance, read these instructions through 

completely.

This FMI PRODUCTS, LLC fireplace and its 

components are safe when installed accord-

ing to this installation manual and operated as 

recommended. Unless you use FMI PROD-

UCTS, LLC components designed and tested 

for this fireplace system, 

YOU MAY CAUSE 

A SAFETY HAZARD!

The FMI PRODUCTS, LLC warranty will 

be voided by, and FMI PRODUCTS, LLC 

disclaims any responsibility for the follow-

ing actions:

A) Modification to the fireplace, components, 

doors, blower, fans or vent system.

B) Use of any component part not manufac-

tured or approved byFMI PRODUCTS, LLC 

in combination with a FMI PRODUCTS, 

LLC fireplace system.

Proper installation is the most important step 

in ensuring safe and continuous operation 

of  the  fireplace.  Consult  the  local  building 

codes as to the particular requirements 

concerned with the installation of all factory 

built fireplaces. This fireplace, when installed, 

must be electrically grounded in accordance 

with local codes or in the absence of local 

codes, with the 

National Electrical Code, 

ANSI/NFPA 70.

The installation must conform with local codes 

or, in the absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1.

 This 

appliance complies with ANSI Z21.88 as a 

vented gas fireplace heater.

SELECTING LOCATION

To  determine  the  safest  and  most  efficient 

location for your fireplace, consider the fol

-

lowing guidelines:
1.  The location must allow for proper clear-

ances (see Figure 1, page 6).

•  Flush  installation  is  recommended 

where living space is limited.

•  Projected installation may be ideal for a 

new addition to an existing finished wall.

•  Corner installation makes use of a space 

that may not normally be used and pro-

vides a wider and more efficient range 

for radiant heat transfer.

2.  Consider a location where the fireplace 

would not be affected by drafts, air con-

ditioning ducts, windows or doors.

3.  A location that avoids the cutting of joists 

or roof rafters makes ventilation installa-

tion easier.

In selecting a location, the following precau-

tions must be observed:

•  Do not connect this appliance to a chim

-

ney system used for solid fuel burning 

fireplace.

•  Due  to  high  temperatures,  do  not  locate 

this appliance in high traffic areas or near 

furniture and draperies.

f i r e - p a r t s . c o m

Содержание DVF32TMHPN-LS

Страница 1: ...ctrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Страница 2: ...the rating plate A conversion kit is supplied with the fireplace State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts SAVE THI...

Страница 3: ...of any component part not manufac tured or approved byFMI PRODUCTS LLC in combination with a FMI PRODUCTS LLC fireplace system Proper installation is the most important step in ensuring safe and cont...

Страница 4: ...tural and propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor ex...

Страница 5: ...fireplace in windy or drafty areas where curtains or other combustible flammable objects can make contact with the fireplace front in high traffic areas 4 Turn fireplace off and let cool before servi...

Страница 6: ...34 3 4 3 BACK VIEW TOP VIEW Left Side Right Side Front Back 24 1115 16 101 2 11 2 11 2 101 2 FRONT VIEW 30 Opening 24 25 RIGHT SIDE 22 5 8 43 1 8 32 Opening 1 7 8 1 7 8 BACK VIEW 39 3 4 26 3 8 3 1 2 3...

Страница 7: ...TS Determine the safest and most efficient loca tion for your FMI PRODUCTS LLC direct vent fireplace Make sure that rafters and wall studs are not in the way of the venting system Choose a location wh...

Страница 8: ...e 5 Minimum Clearances See Thru Shown Combustible Material Drywall 2 x 4 Stud Minimum 1 Clearance from Side Only for See Thru FRAMING Once final location has been determined observing clearances for v...

Страница 9: ...quare Min Figure 12 Rough Opening for Installing Exterior Vent Terminal Vertical Height Depends on Installation 26 3 8 Horizontal Length Depends on Installation 90o Elbow 45o Elbow Figure 13 Vent Open...

Страница 10: ...n line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEA...

Страница 11: ...al codes In the USA follow the current National Fuel Gas Fuel Gas Code ANS Z223 1 also known as NFPA 54 These models are approved for use with FMI PRODUCTS LLC Series rigid type direct vent pipe as su...

Страница 12: ...greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clear...

Страница 13: ...ce from fireplace flue outlet to ceiling Add ceiling thickness vertical rise in an attic or second story and allow for sufficient vent height above roof line You may use one or two 90 elbows in this v...

Страница 14: ...des Note When installing in a chase you should insulate the chase as you would the outside walls of your home This is especially im portant in cold climates Minimum clearance between vent pipes and co...

Страница 15: ...bustible exterior wall 8 1 2 diameter hole if non combustible Frame as necessary Figure 17 Vent Pipe Connections Male Slots Female Locking Lugs Rigid Vent Pipe 4 Three types of vent caps are available...

Страница 16: ...unit is tight and does not come loose before unit is nailed to framing Square vent or long vent configuration Vent pipe must be manipulated at outer end to make final connection Manually secure pipe...

Страница 17: ...t to be used with a vertical termination 1 Determine route your vertical venting will take If ceiling joists roof rafters or other framing will obstruct venting system consider an offset see Figure 24...

Страница 18: ...er the same size as ceiling joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clearance space If ar...

Страница 19: ...vent pipe passes through any oc cupied areas above the first floor including storage spaces and closets you must enclose pipe You may frame and sheetrock enclosure with standard construction material...

Страница 20: ...Configuration Using Two 90 Elbows VENTING INSTALLATION Continued Vertical Termination Configurations Figures 29 through 32 show four different configurations for vertical termination These minimum ve...

Страница 21: ...0 feet USA you may need to decrease the input rating by changing the existing burner orifice to a smaller size Reduce input 4 for each 1 000 feet above sea level Check with your local gas company for...

Страница 22: ...ed P58 12 12 Section Double Wall Pipe Galvanized P58 6 6 Section Double Wall Pipe Galvanized VENTING INSTALLATION Continued Number Description PA58 712 Adjustable 7 12 Section Double Wall Pipe Galvani...

Страница 23: ...within an accessible distance behind louvered opening see Figure 35 You may test blower for operation by turning control knob clockwise just until it clicks on which is the full on position Adjust fa...

Страница 24: ...person An equipment shutoff valve has been included in the appliance s gas supply system You may consider installing an extra gas shutoff valve outside appliance s enclosure check with local codes whe...

Страница 25: ...a leak is detected WARNING Improper installa tion adjustment alteration service or maintenance can cause injury or propertydamage Refertothismanu al For assistance or additional infor mation consult a...

Страница 26: ...ght twig which is placed across top of logs B 5 Figure 44 shows the top view of burner and grate 6 Place logs A as shown in Figure 45 7 Place logs B as shown in Figure 46 page 27 Lift end of log A tha...

Страница 27: ...ued PILOT ELECTRODE ASSEMBLY ADJUSTMENT The pilot assembly is factory preset for the proper flame height Alteration to these set tings may have occurred during shipping and handling If this is the cas...

Страница 28: ...r s normal setting is fully open Do not forget to retighten the air shutter screw Figure 52 Burner Removal BURNER REMOVAL CAUTION Beforeproceeding toopenglassdoororhandlelogs make sure entire unit is...

Страница 29: ...s should be alerted to the hazards of high surface tem peratures andtostayawayfrom the appliance to avoid burns or clothingignition Youngchildren should be carefully supervised when they are in the sa...

Страница 30: ...n may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIG...

Страница 31: ...e technician or gas supplier 9 Turn on all electric power to fireplace 10 Turn gas control knob counterclockwise to ON 11 This valve is equipped with a HI LO fea ture Set fireplace input as desired O...

Страница 32: ...cian replace pilot line 7 Replace control valve see Replacement Parts and Ac cessories page 34 8 Tighten thermocouple or replace 1 Check wiring connection Refer to Wiring Diagram page 33 1 Check elect...

Страница 33: ...e pilot or misaligned electrode at pilot 3 No or low gas pressure OBSERVED PROBLEM Whenignitorbuttonispressed there is no spark at pilot TROUBLESHOOTING Continued 1 Checkelectricalconnections and repl...

Страница 34: ...have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You m...

Страница 35: ...Only Black 01645 REFRACTORY PIECES Front Bottom 25854 Left Right Bottom 25856 Rear 25855 See Thru Only Rear 27374 Peninsula Only Front Bottom Left Right Bottom Rear For Peninsula and See Thru PIEZO I...

Страница 36: ...t and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material l...

Отзывы: