background image

www.fmiproducts.com

54010F

15

4. Install 

firestop spacer in chase at ceiling 

level for safety and reduction of cold air 
movement (see 

Accessories

, page 16).

5.  Do not insulate top of firebox. The opening 

in collar around chimney at top of firebox 
must mot be obstructed (see Figure 27).

6. Before finishing  fireplace enclosure, in-

spect all joints of outer firebox. Seal any 
gaps of outer firebox with noncombustible 
material. Caulk any gaps between nailing 
flange and framing.

OPERATION AND MAINTENANCE GUIDELINES

Continued

•  The glass must be allowed to warm slowly 

and evenly. The tempered glass will with-
stand a gradual temperature rise to 550° F, 
which is more than a normal fire will gener-
ate. Such materials as pitch/wax laden logs, 
very dry mill end lumber and large amounts 
of paper or cardboard boxes. Always keep 
the fire well back from the doors and never 
allow flames to contact the glass.

  WA R N I N G :   F i r e p l a c e s 

equipped with glass doors 
should be operated only with 
doors fully opened or doors fully 
closed. Doors, if left partly open, 
may draw gas and flame out of 
the  fireplace opening creating 
risks of both fire and smoke.

FIREPLACE
STARTER
COLLAR

KEEP THIS
AREA OPEN

Figure 27 - Fireplace Collar Opening

GLASS DOORS

Bi-fold glass doors are optional with this 
fireplace. Check with your local distributor 
for availability.
To install glass doors, refer to installation 
instructions that are included with kit. When 
fireplace is in operation, doors must be fully 
open or fully closed position only or a fire haz-
ard may be created (see Figure 28).
A fireplace equipped with glass doors oper-
ates much differently than a fireplace with an 
open front. A fireplace with glass doors has a 
limited amount of air for combustion. Exces-
sive heat within the fireplace can result if too 
large a fire is built or if combustion air gate is 
not completely open. 
The following tips should be followed to as-
sure that both the fireplace and glass door 
retain their beauty and function properly. 
• Both 

the 

flue damper and glass doors must 

be fully opened before starting fire. This 
will provide sufficient combustion air and 
maintain safe temperatures in firebox.

Doors Fully Closed

Doors Fully Open

Figure 28 - Glass Doors on Fireplace

Cleaning Glass

Clean glass with any commercial glass 
cleaner or soap and water. Do not use any 
abrasive material to clean glass. Do not clean 
glass with any cool water if glass is still hot 
from the fire. To remove doors, refer to instruc-
tions included with glass door kit.

Содержание 36L Series

Страница 1: ...eater approved toANS Z21 11 2 standard AFMI PRODUCTS LLC hood must be installed when using a vent free gas log set see Accessories page 16 This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE and is listed and tested by the PFS Cor poration INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference 36 OPEN CORNE...

Страница 2: ...mmablematerialsonornear the appliance Never leave children unat tended when a fire is burning in the fireplace IMPORTANT Check local codes before installing this fireplace This fireplace model is a wood burning fireplace intended and approved for installation in either residential homes or buildings of standard construction This fireplace system requires the utilization of FMI PRODUCTS LLC s 8 dou...

Страница 3: ...ey are burning Use only fire logs that have been evaluated for the application in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNING Alwaysleaveglass doorsfullyopenedorfullyclosed when operating fireplace WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burns or clothing ignition Young chil...

Страница 4: ...e is even or level with wall Chase Installation type of installation where chimney is enclosed Perpendicular Side Wall applies to minimum clearance between side wall and fireplace opening Nailing Flange extended part on both sides of fireplace face that secures fireplace to wall Termination cap that is placed at end of chimney pipe SELECTING LOCATION To determine the safest and most efficient loca...

Страница 5: ...aterials can be obtained from manufacturer or supplier of noncombustible material The minimum required thickness ofr any material could be obtained by the following formula K factor at 1 thickness required 0 84 For example if the material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness required 0 84 If hearth extension is to be covere...

Страница 6: ... Perpendicular Side Wall OPTIONAL OUTSIDE AIR KIT Models AK4 or AK4F The installation of an outside air kit should be performed during the rough framing of the fire place due to the nature of it s location Outside combustion air is accessed through and exterior wall AK4 or a vented crawl space AK4F See Figure 8 and Accessories on page 16 Avoid installing outside air eyebrow in areas where inlet op...

Страница 7: ... FMI PRODUCTS LLC chimney system consists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maxi mum adaptability to individual site require ments Actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected Each double wall chimney section consists of a galvanized outer...

Страница 8: ...3 4 115 1 2 2 1 64 3 4 120 3 4 2 1 68 1 4 127 1 2 70 130 2 74 1 4 137 1 2 1 2 1 76 3 4 141 1 2 1 2 1 79 3 4 146 3 4 4 Figure 11 Rise and Offset B A Screws Figure 12 Typical Offset Installations WARNING The opening in the collar around the chimney at the top of the fireplace must not be obstructed Neveruseblowninsula tion to fill the chimney enclosure USING CHIMNEY OFFSET To achieve desired offset ...

Страница 9: ...uired clearance between the chimney and the combustible materials When the pipe passes through a framed open ing into a living space above the firestop must be placed onto the ceiling from below as shown in Figure 14 When the pipe passes through a framed opening into an attic space above the firestop must be placed on the attic floor as shown in Figure 15 SUPPORT SECTIONS 12S 8DM The chimney suppo...

Страница 10: ...ich pipe will penetrate roof 2 Determine center point of roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 18 to determine correct opening length and flashing required 4 Remove shingles around opening mea sured Cut out this section Figure 17 Typi...

Страница 11: ...n ingsontherooftopflashing Fol low the installation instructions provided with the termination being used RTL 8DM Collar Flashing Underlap Shingles Figure 21 Terminations Overlap Shingles Top and Sides Caulk Attach Bracket Tabs to Outer Pipe 3 places Secure with Screws 5 Add next sections of pipe until end penetrates roof line Check to see that proper clearances are maintained Extend chimney by ad...

Страница 12: ...s important that combustible materials do not overlap the face itself Brick glass tile or other noncombustible materials may overlap the front face provided they do not obstruct louvered slots or any other opening When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive appropriate for the particular installation WARNING A qualified service person must conn...

Страница 13: ...ole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK T...

Страница 14: ...s log sets that comply with the Standard for Decorative Gas Appliance for Installa tion in Solid Fuel Burning Fireplace ANS Z21 1 60 can be installed in accordance with the National Fuel Gas Code ANS Z223 1 in this fireplace WARNING When using a decorative vented gas log the damper must be removed or per manently locked in the fully open positionandtheglassdoorsmust be in the fully open position C...

Страница 15: ...LLAR KEEP THIS AREA OPEN Figure 27 Fireplace Collar Opening GLASS DOORS Bi fold glass doors are optional with this fireplace Check with your local distributor for availability To install glass doors refer to installation instructions that are included with kit When fireplace is in operation doors must be fully open or fully closed position only or a fire haz ard may be created see Figure 28 A fire...

Страница 16: ... not overload grate or obstruct required air space beneath it Always keep ashes from building up under grate WARNING Risk of fire Re placegratemadeforusewiththis fireplace only See Replacement Parts CHIMNEY Have your chimney system cleaned and in spected regularly to ensure safe and efficient operation TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshootin...

Страница 17: ...rass GA6052 Antique Brass GA6053 CHIMNEY SUPPORT 12S 10DM STORM COLLAR SC1 Used for RT 8DM and RTL 8DM SC2 Used for RTT 8DM and RTTL 8DM ROOF FLASHING V6F 8DM 0 to 6 12 Pitch V12F 8DM 6 12 to 12 12 Pitch FIRESTOP SPACER FS 8DM ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM SQUARE TOP TERMINATION ET 8DM ETO 8DM SQUARE TOP TERMINATION WITH SLIP SECTION ETL 8DM ETLO 8DM ROUND TOP TERMINATION RT...

Страница 18: ...ts com 54010F 18 HIGHT TEMPERATURE TOUCH UP PAINT 106583 01 Not Shown ACCESSORIES Continued OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4F FAN KIT VCBK4C Left VCBK4R Right OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 ...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________...

Страница 20: ...54010 Rev F 09 09 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Отзывы: