FIREPLACE INSTALLATION
Continued
VENTING INSTALLATION
Figure 8 - Air Kit Installation
Secure to Collars with
Duct Tape or Screws
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vent Hood
Required for
Wall Installation
Air Inlet
Termination
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Example 1:
The face of a mantel, bookshelf,
etc. is made of combustible material and pro-
trudes 2
3
/
4
" from the wall on which the fireplace
is installed. The combustible material must be a
minimum of 4" from side of fireplace opening.
Example 2:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 11/16" from the wall on which the
fireplace is installed. The combustible material
can butt up against side of fireplace (i.e. 1"
from fireplace opening.
Figure 6 - Mantel Clearances
Figure 7 - Minimum Side Clearances
0 1 2 3 4 5 6
7 8 9 10 11 12 13 14
11/16
1
3
/
8
2
1
/
16
2
3
/
4
3
7
/
16
4
1
/
8
4
13
/
16
5
1
/
2
6
3
/
16
6
7
/
8
7
9
/
16
8
1
/
4
8
15
/
16
9
5
/
8
No Combustible
Material on Face
of Firebox
Fireplace
Opening
Example 1
Example 2
1" Both
Sides
Minimum 14" from Perpendicular Side Wall
OPTIONAL OUTSIDE AIR KIT
(Models AK4 or AK4F)
The installation of an outside air kit should be
performed during the rough framing of the fire-
place due to the nature of it’s location. Outside
combustion air is accessed through and exterior
wall (AK4) or a vented crawl space (AK4F). See
Figure 8 and
Accessories
on page 16.
Avoid installing outside air eyebrow in areas
where inlet opening may be blocked by snow,
bushes or other obstacles. It should also be
located beyond the reach of children.
CAUTION: Air ducts must
not terminate in attic space or
garage.
The maximum height for the
air vent can not exceed 3 feet
below the flue gas outlet of the
termination.
For further details on installation of outside air
kit, please refer to instructions included with
air kit. For operating instructions, please refer
to your owner’s manual.
Outside air handle is located on left-hand side
of fireplace refractory (see Figure 9 on page
7, Model 36R shown). To close, pull done; to
open, push up. Always open mechanism when
starting a fire to provide adequate outside
combustion air. Close mechanism when not in
use to prevent cold air from entering room.
12
1
/
4
" Ref.
6"
Ref.
12" Min.
9" Min.
1
1
/
2
" Max.
3" Nom.
33°
Combustible
Material
Safe
Zone for
Projection of
Combustible
Materials
Fireplace Opening
Upper
Section of
Fireplace