background image

 

 

 

 

FXBA‐0072‐17               

                              

1 / 42 

 

VITRIOX® ELECTRIC 

 

User manual and technical description 

 

 

 

 

 

 

 

 

 

 

 

Manufacturer: 

 

FLUXANA® GmbH & Co.KG 
Borschelstr.  3 
D‐47551 Bedburg‐Hau 
Tel.  +49 (0)2821 / 48011‐10 
Fax. +49 (0)2821 / 48011‐99 
E‐mail: 

[email protected]

 

Homepage: 

http://www.fluxana.com

 

Service and support

FLUXANA® GmbH & Co.KG 
Borschelstr.  3 
D‐47551 Bedburg‐Hau 
Tel.  +49 (0)2821 / 48011‐10 
Fax. +49 (0)2821 / 48011‐99 
E‐mail: 

[email protected]

 

Homepage: 

http://www.fluxana.com

 

Содержание VITRIOX ELECTRIC

Страница 1: ...Borschelstr 3 D 47551 Bedburg Hau Tel 49 0 2821 48011 10 Fax 49 0 2821 48011 99 E mail info fluxana de Homepage http www fluxana com Service and support FLUXANA GmbH Co KG Borschelstr 3 D 47551 Bedbur...

Страница 2: ...s of the system 4 Transport Setup and Installation 4 1 Delivery 4 2 Unpacking 5 Operating Elements 5 1 Front plate 5 2 Tilted view 5 3 General technical description 5 4 Main screen touch screen 5 5 Se...

Страница 3: ...s of the product include Microprocessor control for the storage of up to 10 different application programs Heat generation by heating elements Oven with thermally insulating materials Inside fusion te...

Страница 4: ...Touchscreen 3 Emergency Stop button 4 Power switch 5 USB Connection 6 Bottom holder Reservoir 7 Bottom insolation 8 Rotation unit 9 Setup station 10 Extra cooling station 11 Mirror Rear side of the o...

Страница 5: ...A 2 AC 16 A IEC 60309 Power plug 1 AC 16 A 2 AC 16 A IEC 60309 Power plug Temperatures Up to 1 250 C Up to 1 250 C Up to 1 250 C Up to 1 250 C Permissible air pressure 6 bar 6 bar 6 bar 6 bar Air con...

Страница 6: ...FXBA 0072 17 6 42 1 4 Models The following drawings are examples but contain the actual dimensions VITRIOX 1 Station VITRIOX 2 Stations continuous operation option COO...

Страница 7: ...FXBA 0072 17 7 42 VITRIOX 2 Stations...

Страница 8: ...FXBA 0072 17 8 42 VITRIOX 4 Stations continuous operation option COO...

Страница 9: ...FXBA 0072 17 9 42 VITRIOX 4 Stations...

Страница 10: ...FXBA 0072 17 10 42 VITRIOX 6 Stations...

Страница 11: ...FXBA 0072 17 11 42...

Страница 12: ...ve Housing Fig 1 Protective housing made of aluminum system profiles and safety glass heat resistant glass in the hot area 1 6 Hood with fan Fig 2 Example installation of a hood with built in fan abov...

Страница 13: ...t setup installation operation or maintenance of the system operation of the system with defective safety devices or incorrectly installed or non functional safety or protection equipment non observat...

Страница 14: ...personnel is not allowed This oven has been designed for commercial use The oven may not be used for the heating of food for people or animals wood grain etc The oven must not be used for heating of...

Страница 15: ...ll persons who must work on the system can view these operating instructions at all times all safety and operational notices on the system are in a good readable condition Damaged or illegible notices...

Страница 16: ...om Fluxana All control and safety equipment may only be operated by trained personnel This information should be completed by the operator Operator Transportation may only be conducted by Setting up m...

Страница 17: ...ee also Upkeep and Maintenance examine the system for visible external damage check to be sure that all safety equipment functions e g EMERGENCY OFF device check all hydraulic or pneumatic tubing for...

Страница 18: ...master switch then secure it with a padlock to ensure it cannot be switched on or pull out the power supply plug Clear and adequately secure the maintenance area Before beginning maintenance and repa...

Страница 19: ...le that you have a respirable dust formation Rules for working at the furnace isolation Use your personal protective equipment Use disposable gloves Use safety glasses with side protection Use dust ma...

Страница 20: ...h cabinet There is danger of fire or explosion 4 Transport Setup and Installation 4 1 Delivery Installation by customer The customer must ensure that the delivered Electrical Fusion Machine is transpo...

Страница 21: ...non alloy steel Corrosion protection should only be removed directly before assembly Warning General Danger Be careful of suspended loads Working under overhead loads is forbidden There is danger of d...

Страница 22: ...surfaces 5 Carefully lower the oven at the installation site taking care of adjacent transportation material Avoid sudden jolts and abrupt setting down 4 2 Unpacking Note The system is carefully pack...

Страница 23: ...FXBA 0072 17 23 42 5 Operating Elements 5 1 Front Plate 1 Display 2 Emergency Stop 3 Power switch 4 USB port 1 4 3 2...

Страница 24: ...FXBA 0072 17 24 42 5 2 Tilted View 1 Crucible 2 Mold 3 FLUXinert sample holder 4 FLUXinert bottom reservoir 5 Tilting bar 6 Autosampler 7 Furnace floor 1 2 3 4 5 6 7...

Страница 25: ...oling air volume can be set in the application The dwell times for all of the machine processes pre melt main fusion main fusion and agitation pouring cooling can be individually set up to 20 differen...

Страница 26: ...st one sample 6 Current temperature 7 Current program step 8 Station button for a new sample 9 Display crucible confirms that a new sample is on the machine blue cooling 10 Extra cooling station 11 Se...

Страница 27: ...s As long as the autosampler is neither loading nor unloading samples the user can open the door at any time The fusion machine is informed that new samples have been loaded when the corresponding sta...

Страница 28: ...ve energy the furnace can be turned off using time control A moon symbol 3 is displayed when night shut off is active The setting is described in section 5 6 7 Selecting the Application When the Appl...

Страница 29: ...ing the Application When the View Application button 11 is pressed a new window opens This window shows the important parameter settings for the active application e g temperatures and times for the i...

Страница 30: ...errors that have occurred Modify Appl Up to 20 applications can be stored and changed here Admin only Time Times for the night shut off are set here Settings Service menu Service only Show Temp Shows...

Страница 31: ...17 31 42 5 6 1 User This window is used to select the user level Lab no password standard user Admin password ABCD enables modification of the applications Service password xxxx enables access to the...

Страница 32: ...the furnace after an emergency stop At the end the autosampler stops behind station 1 The sample must then be removed manually WARNING hot The autosampler must be returned to the zero position with th...

Страница 33: ...ct the service AS position wrong Initialize AS AS not in furnace position Initialize AS Door open Close the door it must always be closed Cooling tome melting time Melting time in the application is t...

Страница 34: ...eating emergency shut off Heating deactivated Contact service 5 6 4 Create New Change Application This program point consists of two windows Change to the next page with Page2 Appl No Shows the applic...

Страница 35: ...ch on off For ICP the sample is poured directly into the Teflon cup there can be no casting dish on the holder is checked Open Furn PF Furnace is opened at the top during the pre melt e g for an oxida...

Страница 36: ...t application number enter the new application number 1 before pressing the Save 3 button The data is stored with the new application number WARNING Data previously stored under the given application...

Страница 37: ...an be changed between 10 and 500 minutes by entering a time The temperature of the oven is shown in red If a second temperature sensor is installed a control temperature is shown in blue This is locat...

Страница 38: ...n this no longer changes the procedure is complete The file RCP0001 csv and RCP0002 csv is generated on the USB stick It contains the application data Application data can be loaded back onto the inst...

Страница 39: ...en performed the first fusion afterwards should be observed We recommend a grain size of 80 Item number VI 0469 For the fusion it is necessary to set the number of stations to be used before the start...

Страница 40: ...BA 0072 17 40 42 For multi station equipment the dust on the top of the X axis and the Y axis must be removed once a shift with a clean and dry cloth Immediately Use the Emergency Stop for All Problem...

Страница 41: ...h are released to the manufacturer The warranty does not cover the costs of disassembly and removal of parts and does not cover the costs of improper handling or failure to follow the instructions for...

Страница 42: ...irectives by FLUXANA GmbH Co KG Borschelstr 3 D 47551 Bedburg Hau This declaration relates exclusively to the machinery in the state in which was placed on the market and excludes components which are...

Отзывы: