GMI-ROT Series - Absolute Rotary Encoder
User Manual
DANGER:
FLUX GmbH declines all responsibility for damages to
things and/or people resulting from improper interventions
carried out by unqualified, untrained, or unauthorized
personnel.
4.1 Environmental conditions of the installation site
The operating environmental conditions necessary for the proper functioning of the
ENCODER
are indicated below.
Environmental data
Temperature range - Standard
(
no additional option in order code
)
Operating
-20°C .. +85°C
Storage
-20°C .. +85°C
Temperature range - Extended
(
contact FLUX for more details
)
Operating
-40°C .. +105°C
Storage
-55°C .. +125°C
Ingress Protection
IP67 (
only for Options: K01, K02 - cable output
)
EMC immunity
complies with EN IEC 61000-6-2
EMC emission
complies with EN IEC 61000-6-4
Max altitude
3000 m above sea level
(
contact FLUX for higher altitudes)
In the installation room there must be no presence of corrosive or harmful gasses or acids,
harmful to both operators and the
ENCODER
itself.
They must not be present in the work area:
●
strong oxidizing agents (acids in general, oxidizing mineral acids, amines compounds,
magnesium salts, aluminum and zinc), corrosive both to the paint and to the other
rubber and plastic parts;
●
scouring powder;
●
potentially explosive atmospheres.
All previous operating and environmental conditions are always valid
if it is not
otherwise explicitly specified.
FLUX GmbH - Austria
2022-04, rev00
23/34