Fluke TS44DLX Скачать руководство пользователя страница 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke Networks product is warranted to be free from defects in material and workmanship under 
normal use and service. The warranty period for the mainframe is 3 years and begins on the date of purchase. 
Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-
MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty 
extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does 
not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, 
contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks 
warrants that software will operate substantially in accordance with its functional specifications for 90 days 
and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that 
software will be error free or operate without interruption.

Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user 
customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks. 
Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet 
or Buyer has paid the applicable international price. Fluke Networks reserves the right to invoice Buyer for 
importation costs of repair/replacement parts when product purchased in one country is submitted for repair 
in another country.

Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, 
free of charge repair, or replacement of a defective product which is returned to a Fluke Networks 
authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit. 
Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination). 
If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident 
or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke 
Networks will provide an estimate of repair costs and obtain authorization before commencing the work. 
Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be 
billed for the repair and return transportation charges (FOB Shipping point).

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY 
CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any 
other provision.

4/04-3

Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA

Содержание TS44DLX

Страница 1: ...TS 44DLX Deluxe Test Set Users Guide PN 2460853 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...est Set in Talk Mode 9 Originating a Call 9 Disconnecting a Call 10 Answering a Call 10 Ground Start 10 Data Lockout Operation 10 Data Safe Practices 10 Data Lockout Override Operation 11 High Voltage...

Страница 4: ...Speaker Timeout 14 Factory Defaults 15 Maintenance 15 Replacing the Battery 15 Replacing or Relocating the Belt Clip 16 Replacing the Line Cord 16 Removing the Old Line Cord 17 Installing a New Line C...

Страница 5: ...oice services It is not always easy to tell the difference between data and voice services The TS44DLX Deluxe Test Set uses unique patented circuitry that prevents disruption of digital data services...

Страница 6: ...ine cord Weatherproof case High voltage lockout in Talk mode Software upgradable Physical Characteristics Housing See Figure 1 The TS44DLX Deluxe Test Set housing is made of high impact plastic The te...

Страница 7: ...e terminals short together Dispose of batteries properly to ensure terminals cannot short Disposal may be restricted by local laws The test set s battery compartment makes battery replacement easy See...

Страница 8: ...rrent than any other circuit in the test set The battery lasts longer if the speaker is used in moderation Audio Controls See Figure 2 The three audio control keys are located on the inside handle of...

Страница 9: ...on the MUTE LED flashes VOL Volume Pressing the VOL key switches the active receiver s sound level between normal and high volume This occurs in Monitor mode and Talk mode The state of the VOL key is...

Страница 10: ...ling numbers See Program Speed Dialing Numbers on page 12 FLASH key Hook Flash The FLASH key interrupts loop current for a timed duration The FLASH key operates only when the test set is off hook When...

Страница 11: ...confirmation tone indicating the test was run and no data was detected Simultaneously the test set measures the dc voltage across Tip and Ring and displays by LED whether the voltage is high low or n...

Страница 12: ...5 seconds If the loop current is normal the LED lights solid Low loop current may indicate a problem on the line Electronic Ringer The electronic ringer is enabled while the test set is on hook HI LO...

Страница 13: ...ac input impedance which allows listening for audio signals without disrupting conversations or data signaling that may be present Either the handset receiver or the speaker can be used to monitor a...

Страница 14: ...Outside Plant and Central Office technicians to perform their normal duties while greatly reducing the possibility of accidentally disrupting data service Accidentally going off hook on a data line w...

Страница 15: ...signals craft provided tones etc Data Lockout Override Operation Normally when the test set detects data it means the operator has accidentally connected to a high speed data line and should immediat...

Страница 16: ...edial a number the LNR key should be the first key pressed after going back off hook If after going off hook any dialing key is pressed the LNR memory is cleared and the value of the pressed key is th...

Страница 17: ...the 9 and 5 enter 9 PAUSE 5551234 When the number is dialed out there will be a pause between the 9 and 5 The duration of a pause is user programmable see Pause Duration on page 14 You can insert a lo...

Страница 18: ...eout The speaker draws more current from the battery than any other circuit on the test set The battery drains quickly when the speaker is left on continuously To extend battery life the test set has...

Страница 19: ...olvent on the test set Doing so will damage the test set Replacing the Battery See Figure 4 To replace the 9 V battery WCaution Be sure to account for all hardware removed Loose or missing hardware co...

Страница 20: ...th a new one Secure the belt clip assembly to the test set housing with the original screw bfp05 eps Figure 5 Belt Clip Replacement To install a second belt clip 1 Remove the blank insert from the tes...

Страница 21: ...the battery door cover to the back of the test set See Figure 4 2 Remove the battery door cover see Figure 4 and battery from the test set 3 Loosen the two screws that hold the line cord to the PCB s...

Страница 22: ...PCB Ring with screw and washer see Figure 8 3 Fasten the black wire lug to the PCB Tip with screw and washer see Figure 8 4 Insert the plastic clip over the line cord strain relief at the base of the...

Страница 23: ...Output ToneFrequency Error 1 5 maximum Tone Level 3 dBm combined typical High versus Low Tone Difference 2 dB 2 dB Memory Dialing Memory Capacity 10 speed dial memories plus one last number redial me...

Отзывы: