Fluke TS44DLX Скачать руководство пользователя страница 14

10

TS44DLX Deluxe Test Set
Users Guide

7

If there is no data and talk battery is present, the 
test set goes off-hook and draws dial tone.

Note

The test set will not go off-hook if the line 
voltage exceeds 140 Vdc.

8

Dial the desired number.

Disconnecting a Call

To disconnect a call, set the Talk/Monitor switch to M or 
remove the test leads from the line.

Answering a Call

1

If a ringing signal is received, set the Talk/Monitor 
switch to T. The test set automatically tests for 
high-speed data on the line.

2

If there is no data and talk battery is present, the 
test set goes off-hook and draws dial tone.

Note

The TS44DLX Deluxe will not go off-hook if the 
line voltage exceeds 140 Vdc.

3

If data is detected, the test set will lockout and 
alarm, indicating data is present.

4

To go off-hook with data present, press the 
Override key sequence (see “Data Lockout 
Override Operation” on page 11).

Ground Start

Ground start lines are typically found on PBX 
installations. To activate an idle ground start telephone 
line, do the following:

1

Set the Talk/Monitor switch to M, and connect the 
test leads to Tip and Ring of the ground start line. 
With a third wire, temporarily short the Tip side of 
the line to earth ground. A wire with an alligator 
clip at each end is often used for this. Do not allow 
clips to short network connections.

2

With the short to earth ground in place, set the 
Talk/Monitor switch to T. When dial tone is 
received, remove the third wire from earth. The 
circuit is now ready for dialing. 

Data Lockout Operation

With the increase in high capacity data lines in the 
distribution system comes the greater risk of disrupting 
data services when working on analog lines. The test 
set is designed to be used by Outside Plant and Central 
Office technicians to perform their normal duties while 
greatly reducing the possibility of accidentally 
disrupting data service.

Accidentally going off-hook on a data line while 
searching for talk battery or dial tone on an unmarked 
terminal block or cable splice could bring down a high-
capacity data lines. To prevent this, the test set provides 
an automatic data lockout function. When the test set, 
with its Talk/Monitor switch in the T position, is 
connected to a Tip and Ring pair, it automatically tests 
the line for high-speed data (data signals that are 
above the human audio range) before going off-hook. 
If data is detected, the test set locks out, preventing 
itself from going off-hook, and it provides a continuous 
audio alarm indicating it has detected data. 

When the test set is locked out, it remains on-hook, it 
does not draw direct current from the line, and it 
presents a high ac impedance to the line to prevent 
disruption of data. The test set can detect and protect 
the following data services: ISDN BRI, ISDN PRI, 56k 
DDS, SW56, T1 and E1, HDSL, IDSL, SDSL, ADSL DMT, 
ADSL CAP, and ADSL LITE.

Data Safe Practices

Always monitor the line for an audible signal before 
attempting to go off-hook to draw dial tone. The data 
detect circuitry on the test set is designed to detect 
data signals above the human audio range. To detect 
data signals within the human audio range, such as 
produced by voiceband modems and subrate DDS 
transceivers, you must listen to the line using the test 
set’s audio monitoring capability. If you hear the hiss of 
a voice band modem or low frequency data transceiver, 
do not move the Talk/Monitor switch to T. If you do 
switch to T, the test set will not lockout because it does 
not detect low frequency data. It will go off hook and 
will interfere with the voice band modem or data 
transceiver. To avoid this, try another line or wait until 
the line is idle.

Содержание TS44DLX

Страница 1: ...TS 44DLX Deluxe Test Set Users Guide PN 2460853 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...est Set in Talk Mode 9 Originating a Call 9 Disconnecting a Call 10 Answering a Call 10 Ground Start 10 Data Lockout Operation 10 Data Safe Practices 10 Data Lockout Override Operation 11 High Voltage...

Страница 4: ...Speaker Timeout 14 Factory Defaults 15 Maintenance 15 Replacing the Battery 15 Replacing or Relocating the Belt Clip 16 Replacing the Line Cord 16 Removing the Old Line Cord 17 Installing a New Line C...

Страница 5: ...oice services It is not always easy to tell the difference between data and voice services The TS44DLX Deluxe Test Set uses unique patented circuitry that prevents disruption of digital data services...

Страница 6: ...ine cord Weatherproof case High voltage lockout in Talk mode Software upgradable Physical Characteristics Housing See Figure 1 The TS44DLX Deluxe Test Set housing is made of high impact plastic The te...

Страница 7: ...e terminals short together Dispose of batteries properly to ensure terminals cannot short Disposal may be restricted by local laws The test set s battery compartment makes battery replacement easy See...

Страница 8: ...rrent than any other circuit in the test set The battery lasts longer if the speaker is used in moderation Audio Controls See Figure 2 The three audio control keys are located on the inside handle of...

Страница 9: ...on the MUTE LED flashes VOL Volume Pressing the VOL key switches the active receiver s sound level between normal and high volume This occurs in Monitor mode and Talk mode The state of the VOL key is...

Страница 10: ...ling numbers See Program Speed Dialing Numbers on page 12 FLASH key Hook Flash The FLASH key interrupts loop current for a timed duration The FLASH key operates only when the test set is off hook When...

Страница 11: ...confirmation tone indicating the test was run and no data was detected Simultaneously the test set measures the dc voltage across Tip and Ring and displays by LED whether the voltage is high low or n...

Страница 12: ...5 seconds If the loop current is normal the LED lights solid Low loop current may indicate a problem on the line Electronic Ringer The electronic ringer is enabled while the test set is on hook HI LO...

Страница 13: ...ac input impedance which allows listening for audio signals without disrupting conversations or data signaling that may be present Either the handset receiver or the speaker can be used to monitor a...

Страница 14: ...Outside Plant and Central Office technicians to perform their normal duties while greatly reducing the possibility of accidentally disrupting data service Accidentally going off hook on a data line w...

Страница 15: ...signals craft provided tones etc Data Lockout Override Operation Normally when the test set detects data it means the operator has accidentally connected to a high speed data line and should immediat...

Страница 16: ...edial a number the LNR key should be the first key pressed after going back off hook If after going off hook any dialing key is pressed the LNR memory is cleared and the value of the pressed key is th...

Страница 17: ...the 9 and 5 enter 9 PAUSE 5551234 When the number is dialed out there will be a pause between the 9 and 5 The duration of a pause is user programmable see Pause Duration on page 14 You can insert a lo...

Страница 18: ...eout The speaker draws more current from the battery than any other circuit on the test set The battery drains quickly when the speaker is left on continuously To extend battery life the test set has...

Страница 19: ...olvent on the test set Doing so will damage the test set Replacing the Battery See Figure 4 To replace the 9 V battery WCaution Be sure to account for all hardware removed Loose or missing hardware co...

Страница 20: ...th a new one Secure the belt clip assembly to the test set housing with the original screw bfp05 eps Figure 5 Belt Clip Replacement To install a second belt clip 1 Remove the blank insert from the tes...

Страница 21: ...the battery door cover to the back of the test set See Figure 4 2 Remove the battery door cover see Figure 4 and battery from the test set 3 Loosen the two screws that hold the line cord to the PCB s...

Страница 22: ...PCB Ring with screw and washer see Figure 8 3 Fasten the black wire lug to the PCB Tip with screw and washer see Figure 8 4 Insert the plastic clip over the line cord strain relief at the base of the...

Страница 23: ...Output ToneFrequency Error 1 5 maximum Tone Level 3 dBm combined typical High versus Low Tone Difference 2 dB 2 dB Memory Dialing Memory Capacity 10 speed dial memories plus one last number redial me...

Отзывы: