15
Maintenance
Factory Defaults
The Restore Defaults function lets you restore all
programmable features to their original factory
settings. This function does not clear stored telephone
numbers. The defaults are:
•
Pause Duration: 4 seconds
•
Hook Flash Duration: 600 ms
•
Speaker Timeout: 2 minutes
•
Exclusive Only Loud Speaker: Disabled
To restore the factory default values:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the pound (#) key. The test set gives a
confirmation tone when the entry is accepted.
Maintenance
W
Warning
Disconnect the clips from any metallic
connections before performing any
maintenance. Read all instructions
completely and understand possible hazards
to end user if repairs are not performed
properly.
Batteries are hazardous to handle. Do not
allow the terminals to be shorted together.
Severe burns or explosion can result if not
handled properly. Dispose of battery
properly to ensure contacts cannot short.
Disposal may be restricted by local laws.
W
Caution
Do not use CRC Cable Clean
®
or any similar
chlorinated solvent on the test set. Doing so
will damage the test set.
Replacing the Battery
See Figure 4.
To replace the 9 V battery:
W
Caution
Be sure to account for all hardware
removed. Loose or missing hardware could
create a hazard for the end user. Be sure to
replace the battery with a good 9 V alkaline
or lithium battery or the test set will not
operate properly.
1
Disconnect the test set from the line and place on
a flat work surface with the battery cover up.
Note
Battery cover screws are retained in the cover
and will not come all the way out of the battery
cover.
2
Use a Phillips screwdriver to loosen only the four
screws attaching the battery door cover to the
back of the test set.Remove the battery door cover.
Do not access or touch the printed circuit or other
areas of the test set.
3
Remove the old battery and properly discard.
Make sure the terminals cannot short.
4
Insert a new 9 V battery into the test set. When
inserting batteries, observe the proper polarity.
5
Check that all sealing surfaces are clean and mate
properly for water resistant seal.
6
Place the battery door cover on the test set and
fasten the four screws securely. Do not over
tighten the screws. The battery door screws should
be torqued to a maximum of 0.904 N-m or 8 in-lb.