1-1

Chapter 1

Introduction

Description

The TS1200 ADSL/POTS Test Set is an analog test telephone used by installers, repair technicians, 
and other authorized personnel for the testing of copper wire, voice subscriber, and ADSL lines. 
The TS1200 can test ADSL lines for throughput, noise margin, and other parameters. It can 
monitor ADSL and POTS lines simultaneously and can test ADSL service in either a snapshot or a 
continuous mode. 

The same circuitry that allows the TS1200 to test POTS services without downing ADSL also 
prevents the test set from disrupting other types of digital data services (xDSL, ISDN) to which 
the test set may have been unintentionally connected. 

Unpacking

Provided in the TS1200 Test Set shipping box are the following items:

AC Adapter/Charger, 12 VDC, 10%, 600 mA

Batteries, NiMH, 1.2V (4)

Line Cord, RJ-45 to ABN

Modular Adapter, DB9/RJ11

Cable, RJ-11 to RJ-11, 7.0 ft

Vehicle Adapter

Users Guide

Содержание TS 1200

Страница 1: ...tober 2005 2005 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...et 2 13 POTS Configuration 2 13 System Configuration 2 15 ADSL Configuration 2 16 Downloading Stored Results to a PC 2 17 Connecting to a PC 2 17 Setting Up the PC Port 2 17 Downloading Results 2 18 3...

Страница 4: ...ii TS1200 Test Set Users Guide Potential Failures in the Copper Loop 4 3 Poor POTS Performance on an ADSL Line 4 3 Data Safe Practices 4 5...

Страница 5: ...eously and can test ADSL service in either a snapshot or a continuous mode The same circuitry that allows the TS1200 to test POTS services without downing ADSL also prevents the test set from disrupti...

Страница 6: ...he connectors If this product is used in a manner not specified by the manufacturer the protection provided by the product may be impaired Registration Registering your product with Fluke Networks giv...

Страница 7: ...1 3 Contacting Fluke Networks...

Страница 8: ...1 4 TS1200 Test Set Users Guide...

Страница 9: ...allows the user to select POTS or ADSL mode and to set or check the system s configuration Light Press the Light key to backlight the menu display LCD and the keypad for easier viewing in dark areas...

Страница 10: ...Speaker key is labeled SPKR Pressing the Speaker Key allows the user to turn the speakerphone on or off Note The transmitter is muted when the speaker is on Pause Mute The Pause Mute key is a dual fu...

Страница 11: ...ed test lead connected to the Tip positive side and with the black test lead connected to the Ring negative side Nothing is shown when the leads are disconnected or the line is not powered Battery Bat...

Страница 12: ...nization Notes Running the ADSL tests in the middle of a line may result in low data rates or no showtime depending upon the length and condition of the line between the TS1200 and the customer s prem...

Страница 13: ...it or press the POTS ADSL key Note Pressing the Home key at any screen will return you to the Home screen Change ADSL Mode 1 Press F2 MODE 2 Press either 1 Multi Mode or 2 G LITE Auto Test Auto test a...

Страница 14: ...Display screens for Manual Test and Auto Test MaxB R Maximum Bit Rate Displays the maximum attainable bit rate Results are presented in kbits s The measured values for upstream and downstream should...

Страница 15: ...ress F1 Alarm To clear an active alarm press the F1 Clear To return to the previous screen press F3 Prev Bits Per Bin Graph A Bits Per Bin Plot is displayed The user can scroll through the plot using...

Страница 16: ...no signals to the line In the Monitor mode the test set is typically used to perform one or more of the following procedures Verification that a line is idle when looking for a line to borrow Listenin...

Страница 17: ...a Lockout mode is provided to help prevent accidental corruption of a data transmission while working on the lines The lockout may be overridden and the test set taken off hook despite the presence of...

Страница 18: ...also make calls while simultaneously testing the ADSL portion of a line Use the POTS ADSL key to toggle between POTS and ADSL Originating a Call To originate a call 1 Clip the test set to Tip and Ring...

Страница 19: ...ERASE will erase the speed dial entry To edit an existing stored number 1 Select number to be edited with Up Down arrow keys or number keys 2 Press F2 Edit 3 Move cursor to either Name or Number using...

Страница 20: ...lt hook flash duration is 600 ms Holding F1 does not repeatedly flash the switch hook Last Number Redial Press F3 LNR Last Number Redialed while in Talk mode The last number dialed is displayed on the...

Страница 21: ...length 3 Press F1 Accept Flash Duration The hook flash duration default value is 600 ms To change the flash duration value 1 Press 2 Flash Duration 2 Use the number keys to select the desired hook fl...

Страница 22: ...Press either 1 Tone or 2 Pulse 3 Press F1 Accept Factory Defaults The Defaults function allows the user to restore all programmable features to their original factory settings Performing this functio...

Страница 23: ...own arrow key Lighter 3 Press F1 Accept Power Timeout The default value is 2 minutes To change power timeout length 1 Press 3 Power Timeout 2 Use the number keys to select the desired light duration 3...

Страница 24: ...DSL POTS and Bootloader versions are displayed 2 Press 3 Prev Stored Results To view erase or send stored results to a PC 1 Press 2 Stored Results 2 Press F1 Send 3 Press F2 View 4 Press F3 Prev 5 If...

Страница 25: ...esults to a PC configured to receive data at 9600 8 N 1 without flow control This section describes how to use Windows HyperTerminal to configure a PC to receive data from a TS1200 To prepare a Window...

Страница 26: ...F2 View to view the results on your TS1200 see Figure 2 3 4 On the TS1200 press F1 Send for each result you want sent The results will be sent to the PC 5 If no data is seen make sure that HyperTermi...

Страница 27: ...2 19 Downloading Stored Results to a PC bdx03 ups Figure 2 3 Selecting and Downloading Stored Results...

Страница 28: ...2 20 TS1200 Test Set Users Guide...

Страница 29: ...rvice personnel Use only specified replacement parts for maintenance Cleaning Clean the display with glass cleaner and a soft lint free cloth Clean the case with a soft cloth dampened with water or wa...

Страница 30: ...e batteries may explode Check with local codes for special instructions Do not attempt to recharge alkaline batteries The batteries may leak corrosive electrolyte or explode Do not open or mutilate th...

Страница 31: ...e To prolong battery life connect the adapter charger while the test set is not in use If the test set will not be used for at least 1 day remove the batteries or connect the charger To charge the NiM...

Страница 32: ...e the wall forward to the first slot Make sure the wall fits correctly into the slot Be careful not to break the leads of the white cable ribbon behind the wall 6 Insert 4 new NiMH or 4 alkaline batte...

Страница 33: ...luke Networks distributor To replace the belt clip 1 Using a Phillips screwdriver remove the two screws that secure the belt clip to the test set housing see Figure 3 2 2 Remove the old belt clip and...

Страница 34: ...ork surface face down Note Cover screws are captive 3 Using a flat blade screwdriver loosen the four battery door screws then remove the battery door 4 Remove one battery on each side of the line cord...

Страница 35: ...sing see Figure 3 4 right 3 Connect the RJ 45 modular connector of the line cord in the housing on the test set see Figure 3 4 left 4 Insert the plastic clip over the line cord strain relief at the ba...

Страница 36: ...Angled Bed of Nails Cord ABN P3218234 Load Coil Standard Line Cord STD with Piercing Pin Clips P2583019 Load Coil Line Cord LC OSP P2583119 Load Coil Line Cord LC CO P2583124 Belt Clip P3218249 Table...

Страница 37: ...ult 30 minutes Battery Type and Life NiMH 8 to 10 hours standard operation Alkaline battery AA 10 to 12 hours standard operation Charge Time Approximately 4 to 5 hours Data Detection and Lockout Capab...

Страница 38: ...Users Guide Certifications and Compliance CAN CSA C22 2 No 60950 1 03 CAN CSA C22 2 No 1010 1 92 CSA C22 2 No 1010 1B 97 UL ANSI 3111 1 Specifications subject to change without notice Table 3 2 Speci...

Страница 39: ...1 summarizes four basic questions that should be answered before troubleshooting ADSL service problems Potential Failures at the Customer Premises Once the basic problems covered in Table 4 1 have be...

Страница 40: ...anent ADSL POTS splitter as shown in Figure 4 1 However the bit rate should first be verified at the NID and the ADSL jack to determine if the limitation is caused by inside wiring or the outside plan...

Страница 41: ...oop for loading bridged taps resistive faults or unbalanced capacitance pair When all else fails and the decision is made to cut over another line to repair the problem ensure that the line has been p...

Страница 42: ...4 4 TS1200 Test Set Users Guide bdx04 eps Figure 4 1 ADSL with and without a Splitter...

Страница 43: ...r dial tone on a block This may create an electrical imbalance on a data line that will disrupt service Once you find the voice line you are searching for then it is OK to test Tip to ground or Ring t...

Страница 44: ...4 6 TS1200 Test Set Users Guide Visit us at www TestEquipmentDepot com...