3-6
TS1200 Test Set
Users Guide
Replacing the Line Cord
WX
Warning
Disconnect from the telephone network when replacing the line cord.
The line cord can be replaced by the user. To get a replacement line cord, contact your local
Fluke Networks distributor.
To remove the old line cord:
1
Turn the Test Set off and disconnect the AC adapter/charger from the test set, if attached.
2
Place the Test Set on a protected work surface, face down.
Note
Cover screws are captive.
3
Using a flat-blade screwdriver, loosen the four battery door screws; then remove the battery
door.
4
Remove one battery on each side of the line cord relief strap.
5
Using a screwdriver or needle-nose pliers, pry up the plastic clip that holds the line cord relief
strap in place (Figure 3-3, left); then remove the clip (Figure 3-3, right).
6
Disconnect the RJ-45 modular connector from housing on test set (see Figure 3-4, left).
7
Slip the line cord out through the hole in the end of the test set.
bdx07.eps