Workgroup Analyzer
Safety and General Specifications
35
Safety and General Specifications
Table 3. General Specifications
Weight
1.7 kilograms (3.8 lbs)
Dimensions
4.1 x 21.1 x 32.8 cm (1.6 x 8.3 x 12.9 in), one
half of a standard 19 in rack mount width
AC input
85 to 265 VAC; 47/63 Hz; 25 watts
Network Analysis Interface
10/100BASE-T, (RJ-45), 100BASE-FX (SC
fiber), 1000BASE-X (SX-GBIC ,LX-GBIC and
TX-GBIC)
Network Analysis interface LEDs
Link, Utilization, Transmit, Collision, Errors
Capture Memory
64 Mbytes (OptiView
TM
Workgroup Pro and Pro
Gigabit models)
Serial Configuration Port
Serial RS-232 (9-pin male)
Management Port
10/100BASE-T (RJ-45) Ethernet
Shock and vibration
Meets requirements of MIL-PRF-28800F for
Class 3 equipment
Laser
Class 1 Laser Product, complies with 21 CFR
1040.10 & 1040.11, CFR(J)
Operating Temperature
10
°
C to 30
°
C (50
°
F to 86
°
F) with up to 95%
Relative Humidity
10
°
C to 40
°
C (50
°
F to 104
°
F) with up to 75%
Relative Humidity
Non-Operating Temperature-20
°
C to +60
°
C (-
4
°
F to +140
°
F
)
Connection to public telephone
network
The analyzer network interfaces are NOT FOR
CONNECTION TO PUBLIC TELEPHONE
SYSTEMS. The analyzer should only be
connected to the public phone network through
regulatory agency compliant modem devices.
Safety
Complies with CSA C22.2 No. 950 Cana-
dian standards, and UL 1950 (US standards)
Complies with European Union directive
EN60950 2
nd
edition.
EMC
Complies with EN61326 Class A.