OptiView
TM
Getting Started Guide
24
Setting the Remote Control PC IP Address
Set this field to specify an offnet PC running the OptiView Browser
TM
remote user
interface software. By setting this field, the analyzer will send its identification
back to the specified PC running the remote user interface software. Set this field
to <none>, <last connected>, or manually enter the IP address of the remote PC
that will be running the OptiView
TM
Browser remote user interface software. <last
connected> is the last remote session to terminate from the analyzer, and that PC’s
IP address is saved into this field.
This address is configured in the Setup | Security screen. Optionally, this address
can be configured through the RS-232 configuration port. This is done so that
analyzers that are placed on network segments other than the one the controlling
PC is on will still automatically show up in the OptiView Browser
TM
list of
available analyzers.
Setting the OptiView Inspector Console Address
The Fluke Networks OptiView Inspector Console
TM
application (formerly called
Network Inspector
TM
) is a Windows 2000
TM
, Windows 98
TM
, and Windows NT
TM
software tool for network engineers, LAN administrators, and network technicians
who maintain LANs (Local Area Networks). The application allows you to
monitor, map, and troubleshoot a LAN segment that could consist of servers,
routers, switches, printers, managed hubs, and clients (hosts and other network
devices).
The OptiView Inspector Console
TM
field is used to enhance the interoperability of
the analyzer and the OptiView Inspector Console
TM
product. The address you enter
should be the IP address of the machine running the OptiView Inspector Console
TM
program. The analyzer will send packets to this address when it is connected to the
network, or when the IP address of the analyzer changes.
These packets assist the OptiView Inspector Console
TM
product in keeping its
information current. OptiView Inspector Console
TM
maintains a special list of all
Fluke Networks' products that are connected to the network and can even be used
to launch a user interface session on any OptiView
TM
Workgroup Analyzer. An
OptiView
TM
analyzer can be used as an agent for the OptiView Inspector
Console
TM
.
OptiView Inspector Console
TM
is purchased separately. A 7 day evaluation copy
can be downloaded from www.flukenetworks.com.
Setting the Analyzer IP Address on the Network Under Test Interface
The Network Under Test Interface represents the 10/100-BASE-T, 100BASE-FX,
and 1000BASE-X ports. It does not include the Management port. To set the IP
address of the Network Under Test Interface, select Setup | TCP/IP. Refer to the
analyzer Help on configuring this screen.