OMNIS
CANNER
User Guide
2 - 2
Certification of Network Installations
OMNIS
CANNER
is designed to efficiently certify cabling installations
through its Autotest feature. Test results, test specifications, and cable
types are organized into Projects. The Project, its test specifications and
cable types are selectable from the OMNIS
CANNER
Project
screen.
OMNIS
CANNER
contains a number of predefined projects, grouped by
test standards, to allow easy and fast operation.
The typical order of operations performed when certifying a cable
installation is as follows:
Preparation
Prior to initial certification, perform the following:
1. Run a self-test by setting the reference for OMNIS
CANNER
and
OMNIR
EMOTE
periodically, e.g. weekly.
2. Select the appropriate
Project
,
Autotest
specification, and
Cable
type.
Certification
Perform the following for each installed cable to be tested:
3. Attach OMNIS
CANNER
to one end of the link, which is typically at the
patch panel in a wiring closet.
4. Attach OMNIR
EMOTE
to the corresponding outlet at the other end of
the cable link.
5. Run Autotest.
6. Save test results.
Completion
At the end of the day or shift, the test results are uploaded using
Scanlink Tools
software.
Scanlink Tools
support the following:
• Upload test results
• Storage of test results to files (Scanlink proprietary format)
• Print test reports
• Export results in CSV format
Содержание OMNIFiber
Страница 1: ...OMNIScanner 2 OMNIFiber ...
Страница 9: ...OMNISCANNER User Guide TOC 6 ...
Страница 25: ...OMNISCANNER User Guide 1 16 ...
Страница 33: ...OMNISCANNER User Guide 2 8 ...
Страница 41: ...OMNISCANNER User Guide 2 16 ...
Страница 103: ...OMNISCANNER User Guide 7 6 ...
Страница 111: ...OMNISCANNER User Guide 9 2 ...
Страница 129: ...OMNISCANNER User Guide A 8 ...
Страница 133: ...OMNISCANNER User Guide C 2 ...
Страница 136: ......