Technical Data
Environmental Specifications
21
2
2.4 Environmental Specifications
Ingress Protection
IP65 (IEC 60529)
Ambient Operating Temperature
6
All
0 to 50°C (32 to 122°F) without cooling
max. 180°C (356°F) with integrated water cooling (Standard)
Internal Operating Temperature
Scanner
0 to 60°C (32 to 140°F)
Laser
automatic switch off at < 5°C (41°F) or > 50°C (122 °F)
Storage temperature
-25 to 65°C (-13 to 149°F)
Humidity
10% to 90%, non-condensing (operating and storage)
Vibration and shock
IEC 60068-2-6, 3 axes, 10 to 150 Hz, operating 2 g above 20 Hz
IEC 60068-2-27, 3 axes, operating: 5 g at 11 ms, 15 g at 6 ms
EMC
EN 61326-1:2013 industrial
KCC
Electromagnetic Compatibility - applies to use in Korea only. Class A Equipment
(Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.
Warm up Period
30 min.
MTBF
40,000 h (about 4.5 years) meantime between failures (MTBF)
for the mechanical scanning system at 48 Hz scan rate
Weight
7 kg (15.4 lbs), incl. air purge
6
at still air (e.g. by using a protective housing)
Содержание MP Series
Страница 16: ...MP Series Users Manual Rev 1 0 Apr 2021 16 1024 pixel 80 Hz scan rate Scan Angle FOV All models 90 ...
Страница 18: ...MP Series Users Manual Rev 1 0 Apr 2021 18 2 2 1 2 Far Focus Figure 2 2 Optical Diagrams Far Focus ...
Страница 37: ...Installation Ethernet 37 5 5 Close the dialog box by pressing on Save ...
Страница 44: ...MP Series Users Manual Rev 1 0 Apr 2021 44 7 2 Mounting Plate A MP MP Figure 7 1 Mounting Plate for Tripod ...