![Fluke MP Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/fluke/mp-series/mp-series_abridged-user-manual_2309932017.webp)
Technical Data
Optical Specifications
17
2
2.2 Optical Specifications
Optical Resolution
D:S
3
Measurement Resolution
(90% energy)
3M
200:1 (IFOV = 5 mrad)
2M
200:1 (IFOV = 5 mrad)
1ML
200:1 (IFOV = 5 mrad)
1MH
200:1 (IFOV = 5 mrad)
Hot Spot Detection (50% energy)
3M
600:1 (IFOV = 1.7 mrad)
2M
600:1 (IFOV = 1.7 mrad)
1ML
600:1 (IFOV = 1.7 mrad)
1MH
600:1 (IFOV = 1.7 mrad)
For more information, see sections 2.2.1
Optical Resolution over Scan Rate
Focus Distances
all
standard focus: 1.52 m (4.9 ft)
special focal distances available, minimal focal distance: 500 mm (20 in)
Note
The focus distance is measured from the front end of the scanner!
2.2.1 Optical Diagrams
2.2.1.1 Standard Focus
Figure 2-1: Optical Diagrams Standard Focus
3
measured as slit response at 20 Hz scan rate, per pixel at focus distance
Содержание MP Series
Страница 16: ...MP Series Users Manual Rev 1 0 Apr 2021 16 1024 pixel 80 Hz scan rate Scan Angle FOV All models 90 ...
Страница 18: ...MP Series Users Manual Rev 1 0 Apr 2021 18 2 2 1 2 Far Focus Figure 2 2 Optical Diagrams Far Focus ...
Страница 37: ...Installation Ethernet 37 5 5 Close the dialog box by pressing on Save ...