6 Commissioning
Page 38 of 67
6
Commissioning
6.1
Safety Messages
In order to prevent personal injury and/or property damage, ensure that
commissioning, flushing and pressure testing work is only carried out by
qualified personnel with appropriate personal protective equipment (PPE) and
suitable work tools.
See Chapter 2 Safety Information.
Risk of injury due to pressure hazards!
Exceeded operating parameters/limits during pressure testing may
cause severe injury or death.
Never exceed the operating parameters/limits of the Argus Ball
Valve as stated on the nameplate.
Risk of injury due to automated operation!
In automated operation moving parts may cause severe injury or
death.
Keep hands, hair and clothing away from all moving parts.
Follow the operating and safety instructions for the actuator.
Risk of property damage due to flushing and/or pressure testing of the piping!
Flushing pressure and/or a (hydrostatic) pressure testing may cause damages to sealing
elements (e.g., at the stem and the stuffing box).
Never exceed the operating parameters/limits of the Argus Ball Valve as stated on
the nameplate.
Operate the Argus Ball Valve into fully open position.
After flushing and/or the pressure testing, check the flange connections again.