OMNITHANE
®
PRODUCT DATA SHEET
SERIES 1
PRODUCT PROFILE
GENERIC DESCRIPTION
Modified Aromatic Polyurethane Primer
COMMON USAGE
A single component, moisture-cured resin, containing a proprietary blend of micaceous iron oxide and zinc to function as
a primer which is field and shop friendly. May be used in OEM manufacturing, potable water and wastewater immersion
with the proper topcoats. May also be used for marginally prepared rusty steel and tightly adhering old coatings for non-
immersion maintenance situations.
COLORS
1216 Grayish-Green
SPECIAL QUALIFICATIONS
NSF: Certified in accordance with ANSI/NSF Std. 61 for potable water applications (for tanks of 1,000 gallons capacity or
greater, pipes 36 inches in diameter or greater or valves 4 inches in diameter or greater) when topcoated (with or without
44-710 Urethane Accelerator) with Std. 61 certified Tnemec coatings.
AISC: Meets AISC requirements for Class B surface with a mean slip coefficient no less than 0.50 and tension creep not in
excess of .005 inches (.13 mm) (SSPC-SP5/NACE 1 & SSPC-SP3). Note: Using other products as primers or topcoats voids
AISC requirements. Contact your Tnemec representative for specific recommendations.
PERFORMANCE CRITERIA
Contact your Tnemec representative for specific test results.
Published technical data and instructions are subject to change without notice. The online catalog at www.tnemec.com
should be referenced for the most current technical data and instructions or you may contact your Tnemec representative
for current technical data and instructions.
© July 17, 2012 by Tnemec Co., Inc.
COATING SYSTEM
SURFACER/FILLER/PATCHER
For information, contact Tnemec Technical Services.
PRIMERS
Self-priming, 90G-1K97, 90-97, H90-97, 91-H
2
O, 94-H
2
O
TOPCOATS
Series 1, 20, FC20, 27, 27WB, 46H-413, 66, L69, L69F, N69, N69F, V69, V69F, 73, 104, 113, 114, 115, L140, L140F, N140,
N140F, V140, V140F, 141, 161, 406, 446, 740, 750, 1028, 1029, 1074, 1074U, 1075, 1075U.
Note: If Series 1 is exterior exposed for 1 year or more it must be scarified or recoated with itself before topcoating.
Scarification or recoating with itself is required if the Series 1 has been exterior exposed for 3 days or longer and Series
113 is the specified topcoat. Note: Series 115 requires Series 44-900 adhesion promoter when topcoating Series 1.
Note: Certain topcoat colors may not provide one coat hiding depending on method of application. Contact your Tnemec
representative.
Published technical data and instructions are subject to change without notice. The online catalog at www.tnemec.com
should be referenced for the most current technical data and instructions or you may contact your Tnemec representative
for current technical data and instructions.
SURFACE PREPARATION
STEEL
Immersion & Severe Exposure: SSPC-SP10/NACE No. 2 Near-White Blast Cleaning.
Non-Potable, Non-Immersion Service: Exterior Exposure: SSPC-SP6/NACE No. 3 Commercial Blast Cleaning. Interior
Exposure: SSPC-SP3 Power Tool Cleaning.
STEEL MAINTENANCE
Abrasive blast cleaning produces the best coating performance. If conditions will not permit this, Series 1 may be applied
over SSPC-SP2 or SP3 Hand or Power Tool Cleaned surfaces in non-potable, non-immersion environments.
GALVANIZED STEEL
Surface preparation recommendations will vary depending on substrate and exposure conditions.
Contact your Tnemec representative or Tnemec Technical Services.
DUCTILE IRON
Recommended for immersion and exterior exposure. Please contact your Tnemec representative for specific
recommendations.
PAINTED SURFACES
Test patch is recommended.
ALL SURFACES
Must be clean, dry and free of oil, grease and other contaminants.
Published technical data and instructions are subject to change without notice. The online catalog at www.tnemec.com
should be referenced for the most current technical data and instructions or you may contact your Tnemec representative
for current technical data and instructions.
TECHNICAL DATA
VOLUME SOLIDS
61.0 ± 2.0% (mixed)
RECOMMENDED DFT
2.5 to 3.5 mils (65 to 90 microns) per coat. Note: NSF certification maximum: 3.5 mils.
CURING TIME
Without 44-710
Temperature †
To Touch
To Handle
To Topcoat
75°F (24°C)
1/4 hour
1 1/2 hours
16 hours
65°F (18°C)
1/4 hour
2 3/4 hours
16 hours
55°F (13°C)
1/4 hour
5 hours
20 hours
† 50% Relative Humidity. Note: Refer to product listings on www.nsf.org for specific potable water return to service
information. Curing time will vary with surface temperature, humidity and film thickness.
Note: When recoating Series 1 with itself, the minimum recoat time is 2 hours at 70°F (21°C).
Ventilation: When used in enclosed areas, provide adequate ventilation during application and cure.
With 44-710: The use of 44-710 can greatly reduce dry to handle cure times. Note: Series 44-710 Accelerator must be used
when the surface temperature falls below 50°F (10°C).
VOLATILE ORGANIC COMPOUNDS
Unthinned: 2.79 lbs/gallon (334 grams/litre)
Thinned 10% (No. 2 or 3 Thinner): 3.20 lbs/gallon (384 grams/litre)
Thinned 10% (No. 49 Thinner): 2.79 lbs/gallon (334 grams/litre)
HAPS
Unthinned: 0.79 lbs/gal solids
Thinned 10% (No. 2 Thinner): 1.98 lbs/gal solids
Thinned 10% (No. 3 Thinner): 0.83 lbs/gal solids
Thinned 10% (No. 49 Thinner): 0.79 lbs/gal solids
THEORETICAL COVERAGE
978 mil sq ft/gal (24.0 m²/L at 25 microns). See APPLICATION for coverage rates.
NUMBER OF COMPONENTS
One
PACKAGING
Five-gallon (18.9L) pails (yielding 3 gallons) and one-gallon (3.79L) cans
NET WEIGHT PER GALLON
21.10 ± 0.60 lbs (9.57 ± .27 kg)
Page 1 of 2
Содержание 6LR-18A
Страница 18: ......
Страница 21: ......
Страница 22: ......
Страница 24: ......
Страница 52: ...GEI 56128 L Copyright 2016 General Electric Company 6 Figure 2A Mounting Figure 2B Mounting ...
Страница 63: ...GEI 56128 L Copyright 2016 General Electric Company 17 Typical 210 to 440 Frame Drip proof Construction ...
Страница 64: ...GEI 56128 L Copyright 2016 General Electric Company 18 Typical 140 to 440 Frame TEFC Construction ...