Chapter 5
5.0 General Specifications
5.01 Environmental
Operating Temperature: 32 to 122 F (0 to 50 C)
Storage Temperature: -10 to 160 F (-23 to 71 C)
Humidity:
0 to 90% Non-condensing
Front Bezel:
NEMA 4X
Case:
ABS Plastic
Dimensions:
See page 5-7
5.02 Input Power
Voltage: 115 or 230 VAC
±
15% (Switch Selectable)
24VDC
±
20%
12VDC +20%, -10%
Frequency:
50/60Hz.
Power Consumption: 10 Watts max
5.1 Input Specifications
The following applies to all inputs in all modes. Inputs
are referenced to the signal ground. All ground terminals
are connected internally. The exception is the RTD input
which is differential but is referenced to ground.
Transient protection: 100V 5nsec
Note: In the event of the specified fault conditions,
unit may temporarily malfunction, but no perma-
nent damage will occur.
5.11 Analog Inputs
Temperature, Pressure, and Flow (1 each)
Current Input:
Input Impedance: 100
Ω
Range: 0-20mA, 4-20mA
Maximum sustained input voltage: 5 VDC
(Fault Condition)
Resolution:
±
0.024% FS
5-1