The following field wiring connections are made to removable screw
terminal blocks supplied with the meter: 

Power, Signal Input, Acknowledge and Hold

Options: Relays & 4-20 mA Output

Figure 1: Rear View of Meter (Connectors)

Wiring Instructions

1. All field connections to be made with insulated copper wire, either

solid or stranded. Tighten all screw terminals to 7 in/lb (0.8 Nm). 
Strip length = 

1

/

2

in (7mm). 

DO NOT

pre-treat wire with solder.

2.

Terminals L

L

: Use AWG #12-18 wire, 600 volt, 60°C. Connect 

only one wire to each terminal on the 9-pin connector.

3.

Terminals AK, H, CM, S+, S-, P-, P+:

Use AWG #12-22 wire, 150

volt, 60°c. If using AWG #20 or smaller wire, up to 2 wires may be 
connected to each terminal. If using AWG #18 or larger wire, only 
one wire may be connected to each terminal.

Model LI1X Universal Process Meter

Instruction Manual

Model LI1X Universal Process Meter

Instruction Manual

11

10

SETUP AND PROGRAMMING

Power, Signal, External Functions & Options Connections

Disconnect power to the meter before making any connections.

Do not connect power or earth ground to any unused or CM terminals.

Observe polarity for DC powered Meters. Applying voltage with
reverse polarity may damage the instrument.

Connecting 230 VAC to a meter specified to accept 115 VAC or con-
necting AC power to a meter specified to accept DC power will result
in damage to the instrument as well as endanger personnel. Keep pri-
mary wires separated from signal cables. 

Notice:

Primary voltages must not be accessible to the user.

Primary wires must be installed in accordance to the applicable 
standards.

!

!

!

AK

H

S

S

P

P

L

L

+

+

-

-

-

+

J3

J2

J1

6

5

4

3

2

1

6

5

4

3

2

1

CM

Label

Main PCB (Lower)

Wire Size

None

Power 12-18

None

Signal, Acknowledge, Hold

12-22

Options PCB (Upper)

J1 

4-20 mA Output

12-22

J2

Relays 1 & 2; NC, NO, Common

12-22

J3

Relays 3 & 4; NC, NO, Common

12-22

Spec Tech Industrial Electric

               www.spectechind.com

888-773-2832

Spec Tech Industrial Electric

               www.spectechind.com

888-773-2832

Содержание LI1 Series

Страница 1: ...Display to 199 990 11 Point Linearization Square Root Extraction with Low flow Cutoff 41 2 Digit Extra Zero Type NEMA 4X Front Panel 2 or 4 Relays 4 20 mA Output Options Lockout Feature Non volatile M...

Страница 2: ...nt dECPt 21 Select Linear Input L or S 21 Select Number Of Calibration Points no PtS 21 General Calibration Scaling Instructions 22 Scale Using Internal Calibration I Cal 22 Calibrate Using an Externa...

Страница 3: ...rs valves etc It is recommended to use this meter in a fail safe system that accommodates the possibility of meter failure or power failure WARNING Hazardous voltages exist within enclosure Installati...

Страница 4: ...Cutoff point will CUTOFF result in a display of zero May be set from 1 count to 100 of full scale user selectable 6 11 POINT Input Range Minimum Span LINEARIZATION Between Inputs 4 20 mA 1 6 mA Number...

Страница 5: ...POWER SUPPLY OUTPUT LOOP Power supply Min loop Max loop RESISTANCE resistance resistance 24 VDC 10 ohms 600 ohms 35 VDC external 600 ohms 1000 ohms 8 Model LI1X Universal Process Meter Instruction Ma...

Страница 6: ...on Manual 11 10 SETUP AND PROGRAMMING Power Signal External Functions Options Connections Disconnect power to the meter before making any connections Do not connect power or earth ground to any unused...

Страница 7: ...AC 4 20 mA Transmitter 3 2 1 Signal Input Selection Array Lockout Jumper L L P P S S C H A O L C M D K Signal Input Selection Array Loop Power Supply 4 20 mA Transmitter AC 3 2 1 Lockout Jumper L L P...

Страница 8: ...Powered Meters Power Signal External Functions Figure 6 Transmitter and Meter Powered from Same DC Power Supply Figure 7 Transmitter and Meter Powered from Separate DC Power Supplies 14 15 24 VDC Powe...

Страница 9: ...tely programmed using just the ENTER button The general method behind SBS is to push ENTER when the meter reads the desired value This value may be a menu title the entire display or just a single dig...

Страница 10: ...ore it starts to scroll to accept it 4 If a flashing digit is not OK or if ENTER was not pushed in time to accept it wait for the digit to scroll and push ENTER when OK 5 Digits will scroll until ENTE...

Страница 11: ...is necessary to first complete an Initial Calibration see Initial Calibration with External Source If Needed on page 20 Scale or Calibrate the Meter To select a Calibration Method apply power with AC...

Страница 12: ...uction Manual 22 23 General Calibration Scaling Instructions Calibration is performed from the front panel using the ENTER but ton It does not require any tools or disassembly of the meter A calibrate...

Страница 13: ...ero flow rate usually zero the high flow rate and the Low flow Cutoff point To program the meter for square root extraction push ENTER When L or S appears push ENTER again The meter will flash L or S...

Страница 14: ...put option can be programmed without a calibrator This option can be calibrated so that a 4 mA out put is produced for any number displayed by the meter The 20 mA output may be programmed to correspon...

Страница 15: ...ct on the alarm status LEDs Automatic Manual Reset Programming There are two ways to reset the relays 1 Automatically when the signal passes through the reset point 2 Automatically manually via the fr...

Страница 16: ...ng inductive loads However installing Resistor Capacitor RC Networks improves this performance and prolongs the life of the meter s relay contacts This suppression can be obtained with RC networks ass...

Страница 17: ...ur screws and washers 11 Reassemble front covers and install connectors Figure 18 Removing Front Bezel Model LI1X Universal Process Meter Instruction Manual Figure 19 Internal View of Meter Option Car...

Страница 18: ...ut 7 set point display 7 Input 8 set point display 8 Input 9 set point display 9 Input 10 set point display 10 Input 11 set point display 11 Alarms Alarm 1 set point reset point Alarm 2 set point rese...

Страница 19: ...truction Manual LIM690FL Rev B 6 99 10500 Humbolt Street Los Alamitos CA 90720 Tel 562 598 3015 Fax 562 431 8507 Spec Tech Industrial Electric www spectechind com 888 773 2832 Spec Tech Industrial Ele...

Отзывы: