background image

   

 

 

   

 

 

KA6

 

 

 

 

 

 

 

Note: 

 

Ø

 

Please read the manual carefully before operating the product. 

 

Warning: 

 

Ø

 

Tubing may have crack due to wear. It results in the overflow of fluid from tubing. In that time human body and instruments may be 

harmed. Users must check frequently and change tubing in time. 

Ø

 

Connect the power cord to the wall socket directly, and avoid using the extended electric wire. 

Ø

 

If the power cord or plug had wear and other damage, please disconnect the plug. (Hold the plug instead of the wire) 

Ø

 

If following situations happened, please turn off the power supply and disconnect the plug. (Hold the plug instead of the wire) 

1. Fluid splash on the pump.   

2. You think the pump need to maintain or repair. 

Ø

 

The user’s power socket must have ground wire, and have reliable grounding. 

 

Note

: The foot pedal switch and other external control plugs must be connected or disconnected in the power-off status to prevent the external 

control interface from being burned 

 

 

 

 
 
 

Содержание FCS KA6

Страница 1: ...FCS KA6 Basic Peristaltic Pump Operation Manual 0 1 2 3456 1 7 7 8 9 88 1 6 A B6 1...

Страница 2: ...If the power cord or plug had wear and other damage please disconnect the plug Hold the plug instead of the wire If following situations happened please turn off the power supply and disconnect the p...

Страница 3: ...4 2 Product Appearance 4 3 Product Keypad Instruction 4 4 External Control Interface Instruction 5 5 Technical Specifications 7 6 Main Functions and Features 8 7 Dimension Drawing 8 8 Maintenance 10...

Страница 4: ...uction l Start stop button Control the pump start and stop press this button once the pump work status change once When the pump runs the start stop indicator light is on When the pump stops the start...

Страница 5: ...e the external control direction and speed indicator light on external control start stop indicator light off 7 External control start stop direction and speed mode the external control start stop dir...

Страница 6: ...External control start stop direction signal all are passive signal 2 The external control plugs must be connected or disconnected in the power off status to prevent the external control interface fr...

Страница 7: ...w rate accuracy 0 5 Display 3 digital LED Control Mechanical keypad External control Switch signal Speed range 0 1 600rpm Speed control Digital knob Speed resolution 0 1rpm 0 100rpm 1rpm 100 600rpm Ex...

Страница 8: ...g functions RS232 communication interface with Shenchen N232 communication protocol RS485 communication interface with standard MODBUS communication protocol High torque heavy flow large suction and l...

Страница 9: ...KA6 9 DZ25 6L Pump Head EasyPump Pump Head 7 2 Product Dimension M6 3L EasyPump...

Страница 10: ...trusion The surface of drive and pump head do not resist strong corrosive liquids please pay attention to this when use the pump Keep the pump rollers clean and dry If the rollers is not clean it will...

Страница 11: ...ty period after confirmation by our technical department we will provide spare parts free of charge Customers will need to bear the shipping cost Exceptions The warranty shall not apply to repairs or...