Isolated External Control Pin Definition 

1)

 

Pin 12 Active WK-RUN/STOP

: Isolated external control start/stop signal input port (Active signal: 5-24V). 

2)

 

Pin 13, Active WK-DIRECT

: Isolated external control direction signal input port (Active signal: 5-24V). 

3)

 

Pin 14, Active-GND

: Isolated external control signal input ground wire. 

 

 

   

  Isolated External Control Wiring Diagram

 

 

l

 

M6 series pump drive could be equipped with foot pedal and dispenser, if you need, please contact us. 

5.

 

Technical Specifications 

Flow rate 

accuracy 

<±0.5% 

Display 

3 digital LED 

Control 

Mechanical keypad 

External control 

Switch signal 

Speed range 

0.1-600rpm 

Speed control 

Digital knob 

Speed 

resolution 

0.1rpm (0-100rpm) 

1rpm (100-600rpm) 

External speed 

control signal 

0-5V, 

0-10V, 4-20mA 

(optional) 

Timing test 

range 

0.5-999s 

Power supply 

AC 220V±10% 

50Hz/60Hz(standard) 

AC 110V±10% 

50Hz/60Hz(optional) 

Temperature 

0-40℃ 

Communication 

RS232 N232 protocol 

RS485Modbus 

protocol 

IP rate 

IP31 

Relative 

humidity 

<80% 

Power 

consumption 

M6-3L 

<80W 

M6-6L 

<180W 

M6-12L 

<300W 

Flow rate   

range 

M6-3L 

0.211-3600ml/min 

M6-6L 

0.3-6000ml/min 

M6-12L 

0.00069-12L/min 

DB15

外控接口

12

13

14

有源信号

5-24V

External Control Interface for DB15

Pin 12

Pin 13

Pin 14

Positive signal 

5-24V

Содержание FCS KA6

Страница 1: ...FCS KA6 Basic Peristaltic Pump Operation Manual 0 1 2 3456 1 7 7 8 9 88 1 6 A B6 1...

Страница 2: ...If the power cord or plug had wear and other damage please disconnect the plug Hold the plug instead of the wire If following situations happened please turn off the power supply and disconnect the p...

Страница 3: ...4 2 Product Appearance 4 3 Product Keypad Instruction 4 4 External Control Interface Instruction 5 5 Technical Specifications 7 6 Main Functions and Features 8 7 Dimension Drawing 8 8 Maintenance 10...

Страница 4: ...uction l Start stop button Control the pump start and stop press this button once the pump work status change once When the pump runs the start stop indicator light is on When the pump stops the start...

Страница 5: ...e the external control direction and speed indicator light on external control start stop indicator light off 7 External control start stop direction and speed mode the external control start stop dir...

Страница 6: ...External control start stop direction signal all are passive signal 2 The external control plugs must be connected or disconnected in the power off status to prevent the external control interface fr...

Страница 7: ...w rate accuracy 0 5 Display 3 digital LED Control Mechanical keypad External control Switch signal Speed range 0 1 600rpm Speed control Digital knob Speed resolution 0 1rpm 0 100rpm 1rpm 100 600rpm Ex...

Страница 8: ...g functions RS232 communication interface with Shenchen N232 communication protocol RS485 communication interface with standard MODBUS communication protocol High torque heavy flow large suction and l...

Страница 9: ...KA6 9 DZ25 6L Pump Head EasyPump Pump Head 7 2 Product Dimension M6 3L EasyPump...

Страница 10: ...trusion The surface of drive and pump head do not resist strong corrosive liquids please pay attention to this when use the pump Keep the pump rollers clean and dry If the rollers is not clean it will...

Страница 11: ...ty period after confirmation by our technical department we will provide spare parts free of charge Customers will need to bear the shipping cost Exceptions The warranty shall not apply to repairs or...

Отзывы: