(1)

 

Pin 1, 0-5V

: Connecting positive pole for the signal that controlling the motor speed, 0-5V connecting wiring port. 

(2)

 

Pin 2, WK-RUN/STOP

: External control start/stop input port (Passive signal: Motor running in normal closed status, motor stop 

running in normal open status.) 

(3)

 

Pin 3, WK-DIRECT

: External control motor running direction signal input port. (Passive signal: Motor running in right in normal 

closed status, motor running in left in normal open status. ) 

(4)

 

Pin 9,

 

WK-SPEED

-

: Connecting signal negative pole that controlling motor speed. 

(5)

 

Pin 10, 0-10V: 

Connecting signal positive pole that controlling motor speed, 0-10V connecting wiring port. 

 

(6)

 

Pin 11, 4-20mA

: Connecting signal positive pole that controlling motor speed, 4-10mA connecting wiring port. 

(7)

 

Pin 15, GND

: Ground wire.

 

Note

:   

1)

 

External control start/stop, direction signal all are passive signal. 

2)

 

The external control plugs must be connected or disconnected in the power-off status to prevent the external control interface from 

being burned. 

 

 

DB15 external control port regular wire sequence as below: 

 

RS232 Communication Pin Definition 

1)

 

Pin 6, 232-T: The host computer sends data port, connect to DB-9 connector Pin 3. 

2)

 

Pin 7, 232-R: The host computer receive data port, connect to DB-9 connector Pin 2. 

3)

 

Pin 15. GND: Ground wire, connect to DB-9 connector Pin 5. 

 

RS485 Communication Pin Definition

 

1)

 

Pin 4, 485-B-: 485 communication signal port, connect with 485 converter    B-. 

2)

 

Pin 5, 485-A+: 485 communication signal port, connect with 485 converter    A+. 

 

模拟信号

0-5V

模拟信号负极

DB15

外控接口

1

2

3

15

9

GND

WK-RUN/STOP

WK-DIRECT

10

11

模拟信号

0-10V

模拟信号

4-20mA

Pin 1

Pin 2

Pin 3

Pin 9

Pin 10

Pin 11

Pin 15

External Control Interface for DB15

Analog Signal 0-5V

WK-RUN/STOP

WK-DIRECT

The Negative Pole of 

Analog Signal

Analog Signal 0-10V

Analog Signal 4-20mA

GND

Содержание FCS KA6

Страница 1: ...FCS KA6 Basic Peristaltic Pump Operation Manual 0 1 2 3456 1 7 7 8 9 88 1 6 A B6 1...

Страница 2: ...If the power cord or plug had wear and other damage please disconnect the plug Hold the plug instead of the wire If following situations happened please turn off the power supply and disconnect the p...

Страница 3: ...4 2 Product Appearance 4 3 Product Keypad Instruction 4 4 External Control Interface Instruction 5 5 Technical Specifications 7 6 Main Functions and Features 8 7 Dimension Drawing 8 8 Maintenance 10...

Страница 4: ...uction l Start stop button Control the pump start and stop press this button once the pump work status change once When the pump runs the start stop indicator light is on When the pump stops the start...

Страница 5: ...e the external control direction and speed indicator light on external control start stop indicator light off 7 External control start stop direction and speed mode the external control start stop dir...

Страница 6: ...External control start stop direction signal all are passive signal 2 The external control plugs must be connected or disconnected in the power off status to prevent the external control interface fr...

Страница 7: ...w rate accuracy 0 5 Display 3 digital LED Control Mechanical keypad External control Switch signal Speed range 0 1 600rpm Speed control Digital knob Speed resolution 0 1rpm 0 100rpm 1rpm 100 600rpm Ex...

Страница 8: ...g functions RS232 communication interface with Shenchen N232 communication protocol RS485 communication interface with standard MODBUS communication protocol High torque heavy flow large suction and l...

Страница 9: ...KA6 9 DZ25 6L Pump Head EasyPump Pump Head 7 2 Product Dimension M6 3L EasyPump...

Страница 10: ...trusion The surface of drive and pump head do not resist strong corrosive liquids please pay attention to this when use the pump Keep the pump rollers clean and dry If the rollers is not clean it will...

Страница 11: ...ty period after confirmation by our technical department we will provide spare parts free of charge Customers will need to bear the shipping cost Exceptions The warranty shall not apply to repairs or...

Отзывы: