For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Installation 5

  Pressure hazard and risk of explosion . This 

pump can develop high pressure when operated with the 
discharge shut off or obstructed. For safe operation, we 
recommend the following:
If not already in the plumbing system, install a pressure 
relief valve in the pump discharge line capable of passing 
the full pump flow at 100 psi (689 kPa). If local code 
requires installation of a pressure relief valve capable of 
handling the full pump flow at a pressure less than  
100 psi (689 kPa), follow the code requirements. Run the 
relief valve discharge to a floor drain or other drain that 
will give adequate runoff.

  Risk of flooding . Be sure that all plumbing 

and fittings are rated to withstand the system pressure 
which you expect the pump to generate.
Follow these instructions for a new installation. This text 
may also be useful when replacing an existing water 
pressure booster:
1.  Decide where’s the best place to install the pump. 

Think about these things:
•  it must be near the main water supply line
•  the pump must be accessible
•  the power cord must reach a power outlet
•  the pump’s LED lights must be visible
•  ease of plumbing
•  space saving

2.  Mount the pump on a solid base in the location you 

have decided on.

3.  Choose a time that will allow you to shut off the 

water to the household while you install the pump.

4.  Shutoff the main water supply valve to 

the household.

5.  Open a nearby faucet to relieve water pressure in the 

plumbing. Once the water pressure is relieved, close 
the faucet.

6.  READ STEP 6 COMPLETELY BEFORE STARTING 

WORK. You must remove a length of pipe from 
the main water supply line to allow installation of 
elbows for the pump. See Figure 2, which depicts 

a typical installation. The locations of the cuts must 
take into consideration the size of the elbows being 
used, the length of the threads in threaded joints or 
the overlap in glued or soldered joints, etc. Position 
the elbows in line with the pump inlet and discharge 
threads. There may be water leakage while cutting 
the pipe. Remove any burrs or shavings caused by 
the cutting tool.

NOTICE: Galvanized pipe may not need to be cut. If 
there is a union close to the pump location, disassemble 
the union and remove (unscrew) pipe back past the 
pump location. Have new lengths of pipe cut and 
threaded to allow for the pump installation.
NOTICE: Both pump ports have 1” NPT threads. 
Depending on your type of connection and the size of 
your home’s piping, you may need to install adapters on 
the ports.
7.  Once the short piece of pipe is removed, the piping 

above the cut can be drained to prevent water 
mess. Place a pail under the opening going to the 
household. Open the highest faucet in the system 
to let in air so the water can fall out of the pipes 
into the pail. Once the system is drained, close 
the faucet.

Sealing Pipe Joints

Use only PTFE pipe thread sealant tape or PTFE-
based joint compounds for making all threaded 
connections to the pump itself. Do not use pipe joint 
compounds on plastic pumps - they can react with 
the plastic in pump components. Make sure that all 
pipe joints in the suction pipe are air tight as well as 
water tight. If the suction pipe can suck air, the pump 
will not be able to pull water from the well.

Figure 2 - Typical household water pressure booster 

installation. Purchase plumbing fittings separately.

Grounded

115V outlet

Pressure

Gauge

Unions

5680 0111

Check Valve

Содержание FP5010

Страница 1: ...e Call 1 800 365 6832 English Pages 2 10 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages...

Страница 2: ...l a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of handling the ful...

Страница 3: ...ore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump...

Страница 4: ...uilding and electrical codes when installing the pump Use rigid pipe when installing this pump Plumbing Pump only clean water with your booster pump To avoid clogging the pump and damaging the shaft s...

Страница 5: ...emove a length of pipe from the main water supply line to allow installation of elbows for the pump See Figure 2 which depicts a typical installation The locations of the cuts must take into considera...

Страница 6: ...PSI See Figure 3 b Press the button The pump will start 16 When the pump stops running after it shuts off automatically the system is at the selected pressure Inspect the pipe and fittings again for...

Страница 7: ...tly after the water demand ceases the pump turns off AUTO RESET mode The AUTO RESET mode is factory set to the ON condition which means that if the pump stops when a DRY RUN condition occurs it will a...

Страница 8: ...life of the bearings The pump seal is water cooled and self lubricating The motor is equipped with an auto reset thermal overload protector If the motor overheats the overload will disable the motor...

Страница 9: ...Heat pit or pump house Pump does not deliver water to full capacity Steel piping if used is corroded or limed causing excess friction Replace with plastic or copper pipe where possible otherwise with...

Страница 10: ...F 35 C Maximum Ambient Temperature 122 F 50 C Dimensions 14 high x 9 wide x 13 long Weight 17 lb 8 kg Incoming Household Pressure 20 PSI 30 PSI 40 PSI 50 PSI Booster pump set at Boosted Household Pre...

Страница 11: ...pompe Si le code de plomberie local requiert l installation d une soupape de d charge prenant en charge un d bit inf rieur 100 lb po2 689 kPa respecter les exigences de ce dernier Risque d incendie ou...

Страница 12: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Страница 13: ...lors de l installation de la pompe Utiliser des tuyaux rigides lors de l installation de la pompe Tuyauterie Utiliser la pompe auxiliaire seulement avec de l eau propre Pour viter d obstruer la pompe...

Страница 14: ...de coudes pour la pompe Voir la figure 2 qui montre une installation typique L emplacement des coupes doit tenir compte de la dimension des coudes utilis s de la longueur des filets des joints filet...

Страница 15: ...de nouveau le tuyau et les raccords la recherche de fuites d eau En cas de fuite appuyer sur le bouton d brancher la pompe fermer la soupape de la conduite principale d alimentation en eau ouvrir un r...

Страница 16: ...n au niveau de l orifice de refoulement Si la pression est inf rieure au r glage s lectionn lorsqu il y a une demande en eau la pompe d marre automatiquement pour pomper l eau la pression s lectionn e...

Страница 17: ...se tenant sur un plancher mouill ou humide Le moteur est lubrifi en usine pour la dur e de vie des roulements billes Le joint de l arbre de la pompe est refroidi l air et est autolubrifiant Le moteur...

Страница 18: ...u le b timent o est situ e la pompe La pompe ne d bite pas au maximum Les tuyaux en acier le cas ch ant sont corrod s ou entartr s causant ainsi un frottement excessif Dans la mesure du possible rempl...

Страница 19: ...9 cm de largeur x 33 cm de longueur 14 po x 22 9 cm x 33 cm Poids 8 kg 17 lb Pression d entr e de la r sidence 20 lb po2 30 lb po2 40 lb po2 50 lb po2 Pompe auxiliaire r gl e Surpression de la r siden...

Страница 20: ...cales requieren la instalaci n de una v lvula de desahogo de presi n capaz de procesar el flujo total de la bomba a una presi n inferior a 100 psi 689 kPa cumpla con los requerimientos de las normas P...

Страница 21: ...su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci...

Страница 22: ...e tuber as r gidas en la instalaci n de esta bomba Plomer a S lo bombee agua limpia con su bomba reforzadora Para evitar obstruir la bomba y da ar la junta del eje no bombee agua que contenga part cul...

Страница 23: ...ra la bomba Consulte la Figura 2 que ilustra una instalaci n t pica Las ubicaciones de los cortes deben tener en cuenta el tama o de los tubos acodados que se utilicen el largo de las roscas en las ju...

Страница 24: ...i n seleccionada Inspeccione nuevamente la tuber a y los accesorios para verificar que no haya fugas Si aparece alguna fuga oprima el bot n desenchufe la bomba cierre la v lvula principal de suministr...

Страница 25: ...o do de AUTO RESET AUTOREPOSICI N El modo de AUTO RESET est configurado de f brica en la posici n activada ON lo cual significa que si la bomba se detiene cuando ocurre una situaci n de marcha en seco...

Страница 26: ...icante El motor viene provisto con un protector de sobrecarga t rmica de reposici n autom tica Si el motor se recalienta el dispositivo de sobrecarga t rmica desactivar el motor para impedir que se da...

Страница 27: ...e la bomba La bomba no entrega agua a toda capacidad Tuber a de acero si se usa corro da u oxidada provocando demasiada fricci n Reemplazar con tuber as de pl stico o de cobre en donde sea posible de...

Страница 28: ...0 C Dimensiones 14 altura x 9 ancho x 13 largo 35 5 cm x 22 9 cm x 33 cm Peso 17 lb 8 kg Presi n de entrada de la residencia 20 PSI 30 PSI 40 PSI 50 PSI Bomba reforzadora configurada para Presi n refo...

Отзывы: