For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Warranty 3

Retain Original Receipt For Warranty Eligibility

Limited Warranty

This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
FLOTEC warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and 
workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months 
from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at FLOTEC’s 
option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only 
and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty 
does not cover repair when normal use has exhausted the life of a part or the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility 
is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or 
replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). 
Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store - contact FLOTEC Customer Service at 
1-800-365-6832.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet 
where it was purchased or to the factory immediately after the discovery of any alleged defect. FLOTEC will subsequently take 
corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after 
the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.

Sewage Pumps

DO NOT return a sewage pump (that has been installed) to your retail store. Contact FLOTEC Customer Service. Sewage pumps 
that have seen service and been removed carry a contamination hazard with them. 
If your sewage pump has failed:
•  Wear rubber gloves when handling the pump; 
•  For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
•  Dispose of the pump according to local disposal ordinances. 

Exceptions to the Twelve (12) Month Limited Warranty

Product

Warranty Period

FP0F360AC, FP0FDC

90 days

FP0S1775A, FP0S1790PCA, FP0S2400A, FP0S2450A, FP0S4100X, FP2800DCC, FPCP-20ULST, FPPSS3000,  FPSC2150A, 
FPSC3150A, FPSC3350A

2 Years

4” Submersible Well Pumps, FP0S3200A, FP0S3250A, FP0S6000A, FPSC1725X, FPSC2200A, FPSC2250A, FPSE3601A, 
FPPSS5000

3 Years

FP7100 Series Pressure Tanks, E100ELT, E3305TLT, E3375TLT, E5005TLTT, E50TLT, E50VLT, E75STVT, E75VLT, FPSC3200A, 
FPSC3250A, FPSC4550A

5 Years

General Terms and Conditions; Limitation of Remedies

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not 
apply to the following: (1) acts of God; (2) products which, in FLOTEC’s sole judgment, have been subject to negligence, abuse, 
accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) 
atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, 
or operation at pressures in excess of recommended maximums.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED 
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION 
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an 
implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights 
and You may also have other rights which vary from state to state.

FLOTEC • 293 Wright Street • Delavan, WI U.S.A. 53115 

Phone: 1-800-365-6832 • Fax: 1-800-526-3757 • Web Site: FlotecWater.com

Содержание FP5010

Страница 1: ...e Call 1 800 365 6832 English Pages 2 10 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages...

Страница 2: ...l a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of handling the ful...

Страница 3: ...ore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump...

Страница 4: ...uilding and electrical codes when installing the pump Use rigid pipe when installing this pump Plumbing Pump only clean water with your booster pump To avoid clogging the pump and damaging the shaft s...

Страница 5: ...emove a length of pipe from the main water supply line to allow installation of elbows for the pump See Figure 2 which depicts a typical installation The locations of the cuts must take into considera...

Страница 6: ...PSI See Figure 3 b Press the button The pump will start 16 When the pump stops running after it shuts off automatically the system is at the selected pressure Inspect the pipe and fittings again for...

Страница 7: ...tly after the water demand ceases the pump turns off AUTO RESET mode The AUTO RESET mode is factory set to the ON condition which means that if the pump stops when a DRY RUN condition occurs it will a...

Страница 8: ...life of the bearings The pump seal is water cooled and self lubricating The motor is equipped with an auto reset thermal overload protector If the motor overheats the overload will disable the motor...

Страница 9: ...Heat pit or pump house Pump does not deliver water to full capacity Steel piping if used is corroded or limed causing excess friction Replace with plastic or copper pipe where possible otherwise with...

Страница 10: ...F 35 C Maximum Ambient Temperature 122 F 50 C Dimensions 14 high x 9 wide x 13 long Weight 17 lb 8 kg Incoming Household Pressure 20 PSI 30 PSI 40 PSI 50 PSI Booster pump set at Boosted Household Pre...

Страница 11: ...pompe Si le code de plomberie local requiert l installation d une soupape de d charge prenant en charge un d bit inf rieur 100 lb po2 689 kPa respecter les exigences de ce dernier Risque d incendie ou...

Страница 12: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Страница 13: ...lors de l installation de la pompe Utiliser des tuyaux rigides lors de l installation de la pompe Tuyauterie Utiliser la pompe auxiliaire seulement avec de l eau propre Pour viter d obstruer la pompe...

Страница 14: ...de coudes pour la pompe Voir la figure 2 qui montre une installation typique L emplacement des coupes doit tenir compte de la dimension des coudes utilis s de la longueur des filets des joints filet...

Страница 15: ...de nouveau le tuyau et les raccords la recherche de fuites d eau En cas de fuite appuyer sur le bouton d brancher la pompe fermer la soupape de la conduite principale d alimentation en eau ouvrir un r...

Страница 16: ...n au niveau de l orifice de refoulement Si la pression est inf rieure au r glage s lectionn lorsqu il y a une demande en eau la pompe d marre automatiquement pour pomper l eau la pression s lectionn e...

Страница 17: ...se tenant sur un plancher mouill ou humide Le moteur est lubrifi en usine pour la dur e de vie des roulements billes Le joint de l arbre de la pompe est refroidi l air et est autolubrifiant Le moteur...

Страница 18: ...u le b timent o est situ e la pompe La pompe ne d bite pas au maximum Les tuyaux en acier le cas ch ant sont corrod s ou entartr s causant ainsi un frottement excessif Dans la mesure du possible rempl...

Страница 19: ...9 cm de largeur x 33 cm de longueur 14 po x 22 9 cm x 33 cm Poids 8 kg 17 lb Pression d entr e de la r sidence 20 lb po2 30 lb po2 40 lb po2 50 lb po2 Pompe auxiliaire r gl e Surpression de la r siden...

Страница 20: ...cales requieren la instalaci n de una v lvula de desahogo de presi n capaz de procesar el flujo total de la bomba a una presi n inferior a 100 psi 689 kPa cumpla con los requerimientos de las normas P...

Страница 21: ...su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci...

Страница 22: ...e tuber as r gidas en la instalaci n de esta bomba Plomer a S lo bombee agua limpia con su bomba reforzadora Para evitar obstruir la bomba y da ar la junta del eje no bombee agua que contenga part cul...

Страница 23: ...ra la bomba Consulte la Figura 2 que ilustra una instalaci n t pica Las ubicaciones de los cortes deben tener en cuenta el tama o de los tubos acodados que se utilicen el largo de las roscas en las ju...

Страница 24: ...i n seleccionada Inspeccione nuevamente la tuber a y los accesorios para verificar que no haya fugas Si aparece alguna fuga oprima el bot n desenchufe la bomba cierre la v lvula principal de suministr...

Страница 25: ...o do de AUTO RESET AUTOREPOSICI N El modo de AUTO RESET est configurado de f brica en la posici n activada ON lo cual significa que si la bomba se detiene cuando ocurre una situaci n de marcha en seco...

Страница 26: ...icante El motor viene provisto con un protector de sobrecarga t rmica de reposici n autom tica Si el motor se recalienta el dispositivo de sobrecarga t rmica desactivar el motor para impedir que se da...

Страница 27: ...e la bomba La bomba no entrega agua a toda capacidad Tuber a de acero si se usa corro da u oxidada provocando demasiada fricci n Reemplazar con tuber as de pl stico o de cobre en donde sea posible de...

Страница 28: ...0 C Dimensiones 14 altura x 9 ancho x 13 largo 35 5 cm x 22 9 cm x 33 cm Peso 17 lb 8 kg Presi n de entrada de la residencia 20 PSI 30 PSI 40 PSI 50 PSI Bomba reforzadora configurada para Presi n refo...