USER CONFIGURATION MODE (Field Calibration Mode)
Field Calibration Method Entry
At the beginning of the calibration method entry menu, the software will allow the user
to start the calibration process or to exit back to normal operation. (See Figures 30-1
& 30-2)
The bottom row of characters will be in focus to indicate that the user can select
between either “Start” or “Exit” by advancing focus.
If “Start” is in focus when advancing to the
next menu, the software will automatically
advance to the calibration menu for the
calibration method the user previously
selected.
Figure 30-1
If “Exit” is in focus when advancing to the
next menu, the software will display a
“save” screen (see Figure 13) to enter “yes
or no” to save your entries.
Figure 30-2
Display Dispense Method
Dispense/Display is a field calibration method by which the user will dispense a known
volume of fluid and the software will keep track of the pulse count during the dispense
operation. The user will then enter the known volume into the display and the
software will calculate a K-factor for the volume dispensed. (See Figure 31-1)
The software will allow the user to
dispense a known volume in order to
create a custom K-factor. This will not over
write the existing factory calibration table.
Figure 31-1
The first screen in this calibration method
will show “run 1” indicating that computer is
waiting for flow to start. (See Figure 31-2)
NOTE:
Pressing any single button while
on this screen will not have any effect.
Pressing both buttons and holding will
allow the user to exit calibration mode.
Figure 31-2