Explanation
Value
Label
■
Select
Off
to disable the alarm
■
Select
Dew point
to trigger an alarm when a
measurement marker detects a cold surface
where there is risk of humidity falling out as liq-
uid water
■
Select
Above
to assign an alarm color to all
pixels above the alarm temperature
■
Select
Below
to assign an alarm color to all
pixels below the alarm temperature
■
Off
■
Dew point
■
Above
■
Below
Alarm
■
Select
Color only
to assign only a color to the
pixels when an alarm is triggered.
■
Select
Silent
to additionally make the font of
the temperature result increase in size and be
displayed against a red background (
i.e.
a visu-
al alarm)
■
Select
Beep
to additionally make the camera
trigger a beep when an alarm is triggered.
■
Color only
■
Silent
■
Beep
Alarm output
Enter an delta alarm value by pressing the naviga-
tion pad left/right.
➲
This label is only available if
Update ref temp
has been previously selected in the
Settings
dialog
box.
N/A
Delta alarm
For information purposes only.
The reference temperature is calculated and updat-
ed ’on the fly’.
➲
This label is only available if
Update ref temp
has been previously selected in the
Settings
dialog
box.
User-defined
Ref temp
Enter a temperature value by pressing the naviga-
tion pad left/right.
User-defined
Alarm temp
10.4.3
Manual adjust/Automatic adjust
Point to
Manual adjust
and press MENU/YES to manually select
level
and
span
set-
tings. The level command can be regarded as the
brightness
, while the span command
can be regarded as the
contrast
.
■
Press the navigation pad up/down to change the level (indicated by an arrow
pointing upwards or downwards in the temperature scale)
■
Press the navigation pad left/right to change the span (indicated by two arrows
pointing away from each other or towards each other)
10
82
Publ. No. 1557882 Rev. a156 – ENGLISH (EN) – February 28, 2006
10 – Camera program
Содержание ThermaCAM B2
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...ThermaCAM B2 User s manual Publ No 1557882 Rev a156 ENGLISH EN February 28 2006...
Страница 10: ...Reg No Status Designation 29 233 400 Pending U S x Publ No 1557882 Rev a156 ENGLISH EN February 28 2006...
Страница 16: ...INTENTIONALLY LEFT BLANK 1 2 Publ No 1557882 Rev a156 ENGLISH EN February 28 2006 1 Warnings cautions...
Страница 26: ...INTENTIONALLY LEFT BLANK 4 12 Publ No 1557882 Rev a156 ENGLISH EN February 28 2006 4 Packing list...
Страница 28: ...INTENTIONALLY LEFT BLANK 5 14 Publ No 1557882 Rev a156 ENGLISH EN February 28 2006 5 System overview...
Страница 110: ...INTENTIONALLY LEFT BLANK 12 96 Publ No 1557882 Rev a156 ENGLISH EN February 28 2006 12 Maintenance cleaning...
Страница 164: ...INTENTIONALLY LEFT BLANK 18 150 Publ No 1557882 Rev a156 ENGLISH EN February 28 2006 18 Theory of thermography...
Страница 191: ......