Setup via keypad and monitor
> To change the date and time settings
5
To change the date and time settings
Date and time are set by the on-board clock. You can change the date and time settings and the timezone or activate
an NTP (Netwerk Time Protocol) Server. The NTP is by default deactivated (127.x.x.x). If the value does not start with
“127”, an NTP is active.
1
Select
General
>
Date/Time
.
2
Do any of the following:
• To change the time: select
Current Time
and use the
Arrow
keys.
• To change the date: select
Current Date
and use the
Arrow
keys.
• To activate the NTP Server: select
NTP Server
and type the server number (max. 12 characters).
• To change the timezone: select
Timezone
and use the
Arrow
keys.
3
Press the
Escape
key.
Configuring the system
About the system configuration
VIEWCOM/E MAX+ is the communication board for up to 4 detector boards (4 x VIP3D.1 or 4 x VIP3D.2) and retrieves
data from these boards by sending a periodic request to all boards. Communication between VIEWCOM/E MAX+ and
the PC goes over TCP/IP. You assign an IP address to VIEWCOM/E MAX+ and you set the number of video signals
that are processed by the detector boards. You can also change the interval for data retrieval.
Note:
If you do not use the NTP server, do not change the default setting (127.x.x.x).
Rack with detector boards and VIEWCOM/E MAX+