![Flin Energy 3kVA-24V Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/flin-energy/3kva-24v/3kva-24v_user-manual_2305475019.webp)
FlinSlim Edge Solar Hybrid Inverter with In-Built Stabilizer
FLIN ENERGY
17
26.5V
27V (default)
27.5V
28V
28.5V
29V
13
Setting voltage point back
to battery mode when
selecting “SBU priority” or
“Solar first” in program 01.
Available options in 48V models:
Battery fully charged
48V
49V
50V
51V
52V
53V
54V (default)
55V
56V
57V
58V
16
Charger source priority: To
configure charger source
priority
If this inverter/charge
mode, charger source
r is working in Line, Standby or Fault
can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charge r is working in Battery mode or Power
saving mode, only sol ar energy can charge battery. Solar
energy will charge ba ttery if it's available and sufficient.
18
Alarm control
Alarm on (default)
Alarm off