FlinSlim Edge Solar Hybrid Inverter with In-Built Stabilizer
FLIN ENERGY
8
3K
5K
WARNING:
Be sure that AC power source is disconnected before attempting to fix the wire to the unit.
4.
Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws.
Be sure to connect PE protective conductor (
)
first.
→
Ground (yellow-green) L
→
LINE
(brown or black)
N
→
Neutral (blue)
3K
5K
5.
Make sure the wires are securely connected.
CAUTION:
Appliances such as air conditioner are required at least 2~3 minutes to restart because it’s required to
have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short
time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer
of air conditioner if it’s equipped with time-delay function before installation. Otherwise, this inverter/charger will
trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the
air conditioner.
PV Connection
CAUTION:
Before connecting to PV modules, please install
separately
a DC circuit breaker between inverter
and PV modules.
WARNING!
All wiring must be performed by a qualified personnel.
WARNING!
It's very important for system safety and efficient operation to use appropriate cable for PV module
connection. To reduce risk of injury, please use the proper recommended cable size as below.