N61e V1.0 or Higher
18/23
TEMP UNIT: C
CUT OFF: 55C
1.
Select the temperature unit
displays on work:
℃
/
℉
.
2.
Stop charging / discharging as the
batteries’ skin temperature gets
up to the preset.
KEY BEEP: ON
BUZZER: MELODY3
INPUT: 10.5V
TRICKLE: OFF
1.
Switch on or off the key beep.
2.
Select one of five melodies (1
…
5) . If the KEY BEEP off, it will
not be available.
1.
The charger will only operate
normally when its input voltage
above this preset value. Or it’ll
alarm and stop charging /
discharging
2.
TRICKLE only fits to NiCd
/NiMH. This function can be
inhibited
TROUBLE SHOOTING
You can’t erase the Error Messages which appear on the LCD, unless you
hold on Press the dial briefly or reset the charger after the faults clearance.
No display:
Display does not work or turns black when connected to power. Check power
supply for proper power. Check input connections for proper contact, making
sure it’s not connected backwards.
Reversed Polarity!
Confirm whether a battery is connected to the output in reverse.
Battery Disconnected!
Confirm whether a battery has connected with the output properly.
Hardware Error!
It happened on leakage or surge current. N61e Power on again. And try to run
Содержание N61e